NOTICE The outside piping must be tilted downward to drain. This helps prevent debris from entering the discharge pipe, and also prevents trapped water from freezing which can damage the pump.
3.Install sump pit cover (not included) to prevent debris from clogging or damaging the pump.
Flood Alarm Models
Testing
NOTE! Disassembly of the motor will void the warran- ty.
Suggested Part Replacement Schedule
Replace pump switch every 2 years. See page 7 for Ridgid cat. #.
Replace float every 2 years. See page 7 for Ridgid cat. #.
Service And Repair
Press and hold test button until alarm sounds. If alarm does not activate after 3 seconds check and/or replace battery then repeat test.
Testing water level
Alarm activates when water level raises the small white float. Test water level sensor operation by lifting it until alarm activates. A 3 to 5 second delay is normal.
Maintenance Instructions
!WARNING
•Always disconnect the electrical supply or unplug the pump before attempting to install, service, relocate, or perform any maintenance. If the power source is out of sight, lock and tag in the open (OFF) position to prevent unex- pected power application. Failure to do so could result in fatal electrical shock. Only a qualified technician should repair this unit. Improper repair could result in fatal electrical shock.
•The motor is oil filled and sealed for cooler running. Allow 2 hours for motor to cool before servicing. Hot oil under pressure could result in severe burns.
1.Check the operation of the Ground Fault Circuit Interrupter (GFCI) on a monthly basis.
2.Keep pump inlet clean and free of all foreign objects. Inspect at least once a year and clean sump as needed.
3.Check pump for proper operation monthly by filling sump with water until pump turns on.
4.Inspect all plumbing connections for any leaks or looseness monthly.
!WARNING
•Service and repair work on this pump must be per- formed by qualified repair personnel. Pump should be taken to a RIDGID Independent Authorized Service Center or returned to the factory. All repairs made by Ridge service facilities are war- ranted against defects in material and workman- ship.
•When servicing this pump, only identical replace- ment parts should be used. Failure to follow these steps may create a risk of flooding, property dam- age, fatal electrical shock, or other serious injury and may also void your warranty.