A03188

Fig. 8—Large Decorative Backplate

A03192

Fig. 9—Decorative Backplate Assembly

8.Match and connect thermostat wires to proper terminals on User Interface backplate. See wiring diagram Fig. 12, 13, and 14.

A — Green = Data A

B — Yellow = Data B

C — White = 24VAC (Com) D — Red = 24VAC (Hot)

NOTE: It is not mandatory that the above color code be used, but each ABCD connection in the system MUST be wired consis- tently. A separate ABCD Connector comes inside packaging and should be used when connecting to furnace (or fan coil). Ensure connector is inserted properly into circuit board. (See Fig. 10)

A B C D

A03193

Fig. 10—4–Wire ABCD Connector

CAUTION: ELECTRICAL OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation.

Improper wiring of the ABCD connector will cause the Evolution Zone System to operate improperly. Check to make sure all wiring is correct before proceeding with installation or turning on power.

9.Push any excess wire into the wall. Seal hole in wall to prevent any air leaks. Leaks can affect operation.

10.Attach Evolution Zone Control™ to the mounting plastic by lining up the plastic guides on the back of the control with the opening on the mounting plastic and push on.

—4—

11.Perform installation of all other system equipment (i.e. zone sensors, dampers, humidifier, ventilator, UV lights, etc.)

12.Turn on power to equipment.

Zone

ZONE

Fan Button

Button

 

 

Display Screen (LCD)

Left-Side

ButtonRight-Side

Button

Time (+/-)

 

 

 

 

 

Button

 

 

 

HEAT

Heat Button

 

 

 

 

 

Hold

 

 

 

 

Cool Button

Button

HOLD

 

 

COOL

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

(+/-) Button

 

 

 

SCROLL

 

System

 

 

 

 

 

Schedule & Vacation

SCHEDULE

VACATION

BASIC

ADVANCED

On/Off Button

 

 

 

 

Basic & Advanced

Program Buttons

 

 

 

 

 

PROGRAM

SETUPS

Setup Buttons

Up/Down

 

 

 

 

 

Scroll Buttons

 

 

 

 

 

 

Schedule

Vacation

Basic

Advanced

Flip Down

 

to program

to start/end

to set time,

for all other

 

temperature

vacation

humidity

settings

Door

schedule

Scroll

up & down

A04038

Fig. 11—Functional Overview

EQUIPMENT WIRING DIAGRAMS:

See wiring diagrams Fig. 12, 13, and 14 for connecting the Evolution Zone Control and Smart Sensors to the Damper Control Module. More information regarding Damper Control set-up and wiring can be found in Damper Control Module Installation Instructions.

See wiring diagram Fig. 12 which includes a variable-speed indoor communicating furnace or FE fan coil, with a 2-speed Puron™ communicating outdoor unit. No additional OAT (outdoor air temperature) sensor is required because the Evolution Zone Control will use the temperature sensor inside the 2-speed unit.

See wiring diagram Fig. 13 for connecting a variable-speed indoor communicating furnace or FE fan coil with a 1-speed air condi- tioning unit (non-communicating outdoor). An Outdoor Air Tem- perature (OAT) sensor may be installed (but is not required) at the indoor furnace or fan coil OAT terminals. When OAT sensor is applied, the Evolution System will provide enhanced system features and benefits.

See wiring diagram Fig. 14 for connecting an FE fan coil with a 1-speed heat pump (non-communicating outdoor unit). When OAT is applied, the Evolution system will provide enhanced system features and benefits.

NOTE: For other applications not listed, refer to the Network Interface Module (NIM) Installation Instructions.

HUMIDIFIER CONNECTION — A 24vac bypass or fan powered humidifier may be installed.

NOTE: Do Not Use a traditional humidistat to control humidifier operation. If a humidifier is installed, let the Evolution™ Zone Control operate humidifier.

Bypass Humidifiers — A bypass humidifier should be wired directly to the furnace or fan coil HUM and 24vac COM terminals. The Evolution Zone Control will automatically energize the HUM output during a call for humidification.

Fan Powered Humidifiers — Most fan powered humidifiers produce internal 24vac in order to energize upon a switch or contact closure. For this application, a 24vac N.O. Isolation Relay (DPST) MUST be used to prevent mixing the internal humidifier power with the indoor equipment transformer. Applying 24vac

Page 4
Image 4
Bryant SYSTXBBUIZ01 instruction manual Large Decorative Backplate, Equipment Wiring Diagrams

SYSTXBBUIZ01 specifications

The Bryant SYSTXBBUIZ01 is a versatile and innovative thermostat designed to optimize the performance and efficiency of heating, ventilation, and air conditioning (HVAC) systems. As part of Bryant's commitment to providing reliable climate control solutions, this unit integrates advanced technologies for seamless user experience and enhanced energy savings.

One of the most notable features of the SYSTXBBUIZ01 is its intuitive interface, which includes a large, user-friendly touchscreen display. This feature makes it easy for homeowners to monitor and adjust their indoor climate with just a few taps. The thermostat supports both heating and cooling modes, allowing users to create customized schedules that fit their lifestyle and maximize comfort throughout the year.

The SYSTXBBUIZ01 utilizes smart technology to provide homeowners with remote access through a mobile application. This capability allows users to adjust their home’s temperature settings from anywhere, ensuring that they can maintain optimal comfort even when away from home. The application also provides energy usage reports, empowering users to make informed decisions about their energy consumption.

In terms of connectivity, the SYSTXBBUIZ01 is equipped with Wi-Fi capability, enabling easy integration with existing smart home systems. This feature allows for voice command controls via compatible virtual assistants, adding an extra layer of convenience to everyday operations.

The thermostat is designed to be compatible with a variety of HVAC systems, including single-stage and multi-stage systems, ensuring broad applicability in many homes. Additionally, the device includes advanced sensors that monitor temperature and humidity levels to provide precise climate control, further enhancing energy efficiency and comfort.

Energy-saving features are a significant highlight of the SYSTXBBUIZ01. The thermostat is equipped with adaptive recovery technology, which learns the heating and cooling patterns of the home, allowing it to optimize operation schedules for maximum efficiency. Additionally, it includes features like geofencing, which adjusts the temperature based on the homeowner’s location, further promoting energy conservation.

The Bryant SYSTXBBUIZ01 stands out as a resilient and effective solution for modern home climate control, combining user-friendly design, smart functionalities, and energy-saving technologies. Its advanced features make it an ideal choice for anyone looking to enhance their home’s comfort and efficiency.