Bryant SYSTXBBUIZ01 instruction manual Equipment Summary Menu, Install Menu, Setup Menu

Models: SYSTXBBUIZ01

1 16
Download 16 pages 51.4 Kb
Page 8
Image 8

EQUIPMENT SUMMARY MENU

EQUIPMENT SUMMARY

FURNACE

355MAV0420

AC

598BNX024

FILTER

EAC

HUMIDIFIER

YES

UV LIGHTS

YES

ZONES

1234

BACK

 

A04108

Fig. 21 — EQUIPMENT SUMMARY

An example screen is shown in Fig. 21:

This screen shows indoor unit type and model number, outdoor unit type (and model number if a 2-speed unit), filter type, any accessories that are installed, and how many zones are recognized.

INSTALL MENU

INSTALL

TO ADD, UNINSTALL OR

RE-INSTALL EQUIPMENT,

PRESS RIGHT SIDE

BUTTON

BACK INSTALL

A03202

Fig. 22 — INSTALL

This menu item will perform start-up process in order to learn all equipment in system. Press right side button to initiate the process. See Fig. 22.

SETUP MENU

This menu has several layers, allowing modification of equipment settings. No settings will need to be made at equipment (i.e. DIP switches on a furnace). All configuration settings made effective from this menu will override equipment configuration made by dip switches. Fig. 23 shows all the information that can be found in the SETUP menu.

SETUP

THERMOSTAT

FURNACE

HEAT PUMP

ZONING

ACCESSORIES

SYSTEM MAINTENANCE

BACK SELECT

A04089

Fig. 23 — SETUP MENU

Setup = THERMOSTAT:

AUTO MODE SETUP:

Enable/Disable Auto Changeover mode (default=Enable).

Auto Changeover Time may be adjusted 5 to 120 minutes, (default = 30 minutes).

When Auto mode is enabled (factory default) a change from heat to cool (or vice versa) will not occur until an opposite mode demand has existed for 30 minutes. If the set point is changed, the 30 minute timer is deleted.

HEAT/COOL DEADBAND:

0 to 6 degrees, (default = 2°).

A minimum difference of 2° is enforced between heating and cooling desired temperatures. This will allow one setting to pushthe other to maintain this difference.

—8—

OFFSETS: This option allows calibration (or deliberate miscali- bration) of the temperature and humidity sensors. These offsets are added to the actual temperature/humidity values (defaults = 0).

Zone 1 Offset: -5 to +5 degrees.

Outside Temp Offset: -5 to +5 degrees.

Humidity Offset: -10 to +10 percent.

CYCLES PER HOUR:

Maximum cycles per hour = 4 (default) or 6.

Anticipator = 1 to 9 (default=3). This adjusts sensitivity to zone temperature changes. 1 = most sensitive, 9 = least sensitive.

PROGRAMMING:

On or Off (default=On)

Periods Per Day = 2 or 4 (default=4)

Programmable Fan On/Off (default=Off). If ON is selected, fan can be set to Auto, Low, Med, or High independently in each zone.

SMART RECOVERY:

On or Off, (default=On)

Applies to programmable operation only. Will start recovery 90 minutes prior to schedule change in both heating and cooling mode.

ENGLISH/METRIC DISPLAY:

°F or °C, (default = °F)

RESET FACTORY DEFAULTS:

Program Schedule:

Yes/No to reset back to Energy Star default Time and Temp schedules.

User Settings:

Yes/No to reset the user settings in the Advanced Setup to factory default settings.

Install Settings:

Yes/No to reset install settings in Install/Service menus to factory default settings.

Last 10 Faults:

Yes/No to reset last 10 faults under Service Info menu.

Setup = FURNACE:

Upon a first time start-up of the Evolution Zone Control™, the furnace DIP switch settings will be copied to the furnace setup menu. Any changes can then be made from the Evolution Zone Control™.

AIRFLOW:

COMFORT (default)

EFFICIENCY

Selects the airflow of the furnace when heating. EFFICIENCY is the airflow used to meet specified ratings, COMFORT is a decreased airflow used to increase the output air temperature and provide increased comfort.

AC AIRFLOW:

EFFICIENCY

COMFORT (default)

MAXIMUM

Selects the airflow of the furnace when cooling. COMFORT is a decreased airflow used to improve humidity control. EFFI- CIENCY is the airflow used to meet specified ratings. MAXI- MUM is a fixed airflow of 400 CFM/ton based on the outdoor unit size.

DEHUM AIRFLOW:

NORMAL (default)

HIGH

Page 8
Image 8
Bryant SYSTXBBUIZ01 instruction manual Equipment Summary Menu, Install Menu, Setup Menu

SYSTXBBUIZ01 specifications

The Bryant SYSTXBBUIZ01 is a versatile and innovative thermostat designed to optimize the performance and efficiency of heating, ventilation, and air conditioning (HVAC) systems. As part of Bryant's commitment to providing reliable climate control solutions, this unit integrates advanced technologies for seamless user experience and enhanced energy savings.

One of the most notable features of the SYSTXBBUIZ01 is its intuitive interface, which includes a large, user-friendly touchscreen display. This feature makes it easy for homeowners to monitor and adjust their indoor climate with just a few taps. The thermostat supports both heating and cooling modes, allowing users to create customized schedules that fit their lifestyle and maximize comfort throughout the year.

The SYSTXBBUIZ01 utilizes smart technology to provide homeowners with remote access through a mobile application. This capability allows users to adjust their home’s temperature settings from anywhere, ensuring that they can maintain optimal comfort even when away from home. The application also provides energy usage reports, empowering users to make informed decisions about their energy consumption.

In terms of connectivity, the SYSTXBBUIZ01 is equipped with Wi-Fi capability, enabling easy integration with existing smart home systems. This feature allows for voice command controls via compatible virtual assistants, adding an extra layer of convenience to everyday operations.

The thermostat is designed to be compatible with a variety of HVAC systems, including single-stage and multi-stage systems, ensuring broad applicability in many homes. Additionally, the device includes advanced sensors that monitor temperature and humidity levels to provide precise climate control, further enhancing energy efficiency and comfort.

Energy-saving features are a significant highlight of the SYSTXBBUIZ01. The thermostat is equipped with adaptive recovery technology, which learns the heating and cooling patterns of the home, allowing it to optimize operation schedules for maximum efficiency. Additionally, it includes features like geofencing, which adjusts the temperature based on the homeowner’s location, further promoting energy conservation.

The Bryant SYSTXBBUIZ01 stands out as a resilient and effective solution for modern home climate control, combining user-friendly design, smart functionalities, and energy-saving technologies. Its advanced features make it an ideal choice for anyone looking to enhance their home’s comfort and efficiency.