Bryant SYSTXBBUIZ01 Setup = FAN Coil, Setup = Heat Pump / AC, Setup = Zoning, Setup = Accessories

Models: SYSTXBBUIZ01

1 16
Download 16 pages 51.4 Kb
Page 9
Image 9

NORMAL airflow adjustment is used during dehumidifying. If duct sweating is an issue, selecting HIGH will increase the dehumidifying airflow and reduce the sweating.

LOW HEAT RISE:

ON

OFF (default)

Set this to ON if the system contains a bypass humidifier. The ON setting will increase the furnace low heat airflow.

STAGING:

SYSTEM (default)

LOW

HIGH

Controls the staging of the furnace. SYSTEM setting will allow the Evolution Zone Control™ to determine furnace staging. LOW will only run the low stage of furnace heat. HIGH will only run the high stage of furnace heat.

OFF DELAY:

90 seconds

120 seconds (default)

150 seconds

180 seconds

Amount of time the blower will continue to run after heating has shut off.

LOCKOUT TEMP:

NONE (default)

+5 to 55 deg F

Appears on dual fuel systems only (furnace with heat pump). Outside temperature above which the furnace will NOT run.

Setup = FAN COIL:

HP/AC AIRFLOW:

EFFICIENCY

COMFORT (default)

MAXIMUM

Selects the airflow of the fan coil when heating or cooling with a heat pump (or cooling with an AC unit). COMFORT is a decreased airflow used to improve humidity control. EFFI- CIENCY is the airflow used to meet specified ratings. MAXI- MUM is a fixed airflow speed of 400 CFM/ton based on the outdoor unit size.

DEHUM AIRFLOW:

NORMAL (default)

HIGH

Normal airflow adjustment used during dehumidifying. If duct sweating is an issue, selecting HIGH will increase the dehumidi- fying airflow speed and reduce the sweating.

HEATER SIZE:

(choices dependent upon fan coil model)

This will show the heater size entered during the start-up process. This value can be changed to another value (limited by the model number of the fan coil). If the electric heater is self-identifying, this value is not shown.

Setup = HEAT PUMP / AC:

COOLING LOCKOUT:

NONE (default)

45° F.

50° F.

55° F.

Outside temperature below which cooling will not be provided.

—9—

ENTERED SIZE:

(dependent on indoor unit model)

Size of the outdoor unit entered during the start-up process. If the outdoor unit is a communicating model, this value will not be shown. This size can be changed here but is limited to sizes that the indoor unit can handle.

DEFROST INTERVAL:

30 minutes

60 minutes

90 minutes

120 minutes (default)

Time interval at which defrost cycles can occur on a heat pump.

ELECT HEAT LOCKOUT / LOCKOUT TEMP:

NONE (default)

+5 to 55 deg. F

Outside temperature above which the electric heat will not operate. In dual fuel applications, heat pump will not operate below selected temperature.

HIGH COOL LATCH:

NONE (default)

80 - 110 deg F

Outside temperature above which only the high speed (of a 2-speed outdoor unit) will run when cooling.

Setup = ZONING

DISABLE ZONING

No (default)

Yes

If Yes is selected, zoning is disabled and all dampers open. The system will run unzoned using the Zone 1 sensor.

ZONE OFFSETS:

Zone Temperature Offsets (defaults = 0) Range -5° to +5°

This option allows actual temperature offset for each zone, allowing calibration (or deliberate mis-calibration) of each sensor.

AIRFLOW LIMITS:

Low

Medium

High (default)

Maximum

Zone airflow limit, which is selectable for each zone. Low, Medium, and High allows a relative noise/airflow relationship in a zone (i.e. comfort vs. noise). Maximum allows unlimited noise/airflow (i.e. maximum airflow allowed).

Setup = ACCESSORIES

FILTER TYPE:

MEDIA (i.e. TrueSense™)

EAC

MEDIA+EAC (i.e. TrueSense™)

CLEAN INTERVAL: 30 to 180 days (of actual blower operation). (Default = 90)

Interval at which the Clean Filter notification will turn on. Applies to EAC filter selection only.

HUMIDIFIER INSTALLED:

NO

YES

If YES, indicates to the system whether a humidifier is installed and enables humidification functions.

CHANGE PAD INTERVAL: 1 to 24 months of humidifier operation (default=6 months)

Page 9
Image 9
Bryant SYSTXBBUIZ01 instruction manual Setup = FAN Coil, Setup = Heat Pump / AC, Setup = Zoning, Setup = Accessories

SYSTXBBUIZ01 specifications

The Bryant SYSTXBBUIZ01 is a versatile and innovative thermostat designed to optimize the performance and efficiency of heating, ventilation, and air conditioning (HVAC) systems. As part of Bryant's commitment to providing reliable climate control solutions, this unit integrates advanced technologies for seamless user experience and enhanced energy savings.

One of the most notable features of the SYSTXBBUIZ01 is its intuitive interface, which includes a large, user-friendly touchscreen display. This feature makes it easy for homeowners to monitor and adjust their indoor climate with just a few taps. The thermostat supports both heating and cooling modes, allowing users to create customized schedules that fit their lifestyle and maximize comfort throughout the year.

The SYSTXBBUIZ01 utilizes smart technology to provide homeowners with remote access through a mobile application. This capability allows users to adjust their home’s temperature settings from anywhere, ensuring that they can maintain optimal comfort even when away from home. The application also provides energy usage reports, empowering users to make informed decisions about their energy consumption.

In terms of connectivity, the SYSTXBBUIZ01 is equipped with Wi-Fi capability, enabling easy integration with existing smart home systems. This feature allows for voice command controls via compatible virtual assistants, adding an extra layer of convenience to everyday operations.

The thermostat is designed to be compatible with a variety of HVAC systems, including single-stage and multi-stage systems, ensuring broad applicability in many homes. Additionally, the device includes advanced sensors that monitor temperature and humidity levels to provide precise climate control, further enhancing energy efficiency and comfort.

Energy-saving features are a significant highlight of the SYSTXBBUIZ01. The thermostat is equipped with adaptive recovery technology, which learns the heating and cooling patterns of the home, allowing it to optimize operation schedules for maximum efficiency. Additionally, it includes features like geofencing, which adjusts the temperature based on the homeowner’s location, further promoting energy conservation.

The Bryant SYSTXBBUIZ01 stands out as a resilient and effective solution for modern home climate control, combining user-friendly design, smart functionalities, and energy-saving technologies. Its advanced features make it an ideal choice for anyone looking to enhance their home’s comfort and efficiency.