Interval at which the Change Humidify Pad notification will be displayed.

HUMIDIFY WITH FAN:

NO (default)

YES

If YES, the humidifier will run with Continuous Fan operation if there is a humidify demand.

VENTILATOR:

NOTE: Only appears if ventilator is installed.

CLEAN INTERVAL:

60 to 180 days of actual operation (default=90)

Interval at which the Clean Ventilator Pre-filter notification will turn on.

UV LIGHTS INSTALLED:

NO

YES

If YES, indicates to the system whether UV lights are installed.

CHANGE INTERVAL:

6 to 48 months operation time (default=12 months)

Interval at which the Change UV Lights notification will be displayed.

Setup = SYSTEM MAINTENANCE

REMIND OWNER OF ROUTINE MAINTENANCE EVERY:

This setup is used to adjust the timer interval in which the normal System Maintenance notification is turned on for the homeowner.

Range= OFF, 6 to 24 months, (default=12 months)

CHECKOUT MENUS

The Checkout menu will show the equipment installed in the system. A sample checkout menu is shown in Fig. 24.

CHECKOUT

FURNACE

HEAT PUMP HEATING

HEAT PUMP COOLING

HUMIDIFIER

ZONING

VENTILATOR

BACK SELECT

A03204

Fig. 24 — CHECKOUT MENUS

Checkout = FURNACE

Make sure the furnace is properly installed before continuing.

LOW HEAT RUNTIME: 5 min.

HIGH HEAT RUNTIME: 5 min.

This menu item allows the furnace to be exercised. First, a low heat runtime and high heat runtime are selected. Range = 5 - 120 min.

If only the low heat is to be exercised:

The furnace will execute its ignition start-up sequence. This sequence will be displayed on the Evolution Zone Control screen. After the gas valve and blower motor turn on, the screen will automatically change to FURNACE CHECKand show the current operating status of the furnace.

Checkout = FAN COIL

ELECTRIC HEAT CHECK

ELECTRIC HEAT RUNTIME: 5 min., Default time = 5 min., Range = 0 - 120 min.

If you have a fan coil with electric heaters, this menu item will allow the heaters to be exercised.

—10—

With self-identifying electric heaters, three stages of electric heat are available to be exercised in any combination. Non-identifying heaters will only provide one stage of heat.

Enter the run time (in minutes) of each stage of heat to be exercised then press START (right-side button). The display will change to show the fan coil’s operating status.

Checkout = HEAT PUMP HEATING

HIGH HEAT RUNTIME: 5 min.

LOW HEAT RUNTIME: 5 min.

DEFROST: NO

The heat pump heating mode can be exercised with this menu option. With a 2-speed heat pump, a low heat runtime and a high heat runtime are independently selectable to exercise. A defrost cycle is also selectable. Default time = Fixed 5 min. minimum, range = 5 - 120 min.

Checkout = HEAT PUMP COOLING OR AC COOLING

HIGH COOL RUNTIME: 5 min.

LOW COOL RUNTIME: 5 min.

The heat pump cooling mode (or AC cooling mode) can be exercised with this menu option. With a 2-speed heat pump or AC unit, a low cool runtime and a high cool runtime are independently selectable to exercise. The display will change to show the heat pump or AC operating status. Default time = Fixed 5 min. minimum, range = 5 - 120 min.

Checkout = HUMIDIFIER

OFF

ON

The humidifier can be exercised On and Off with this menu option.

Checkout = VENTILATOR

SPEED:

OFF

LOW

HIGH

The ventilator can be exercised through all of its operating speeds with this menu option.

Checkout = ZONING

DUCT ASSESSMENT

This is the same Duct Assessment that runs on first start-up.

Measures duct capacity for each zone. The Duct Assessment will perform an airflow measurement on each zone and determine the relative size of each zone along with damper leakage. This assessment will require approximately 1 minute for each zone in the system.

NOTE: A Duct Assessment will automatically occur every 24 hours at 1:00 p.m. to check system static and calibrate dampers.

SENSOR DAMPER CHECK:

The Sensor/Damper Check allows the installer to check each zone damper for operation, as well as insure the zone sensor corre- sponds to that particular zone.

When first initiated, the Zone 1 damper will fully OPEN, and all other zones will CLOSE. Using the scroll button, the installer can select each zone and verify the damper is fully open while all other dampers remain closed.

After proper damper operation has been verified, the installer can now check and verify that each remote room sensor corresponds to the proper zone damper in the same zone. Start from the top and highlight zone 1 to open damper. Temporarily disconnect any other zone remote room sensor (at sensor location). That zone damper will now OPEN, while the Zone 1 damper will close. EXAMPLE: If the Zone 2 remote room sensor is disconnected, the Zone 2 damper will now open as indicated on the User Interface

Page 10
Image 10
Bryant SYSTXBBUIZ01 instruction manual Checkout Menus

SYSTXBBUIZ01 specifications

The Bryant SYSTXBBUIZ01 is a versatile and innovative thermostat designed to optimize the performance and efficiency of heating, ventilation, and air conditioning (HVAC) systems. As part of Bryant's commitment to providing reliable climate control solutions, this unit integrates advanced technologies for seamless user experience and enhanced energy savings.

One of the most notable features of the SYSTXBBUIZ01 is its intuitive interface, which includes a large, user-friendly touchscreen display. This feature makes it easy for homeowners to monitor and adjust their indoor climate with just a few taps. The thermostat supports both heating and cooling modes, allowing users to create customized schedules that fit their lifestyle and maximize comfort throughout the year.

The SYSTXBBUIZ01 utilizes smart technology to provide homeowners with remote access through a mobile application. This capability allows users to adjust their home’s temperature settings from anywhere, ensuring that they can maintain optimal comfort even when away from home. The application also provides energy usage reports, empowering users to make informed decisions about their energy consumption.

In terms of connectivity, the SYSTXBBUIZ01 is equipped with Wi-Fi capability, enabling easy integration with existing smart home systems. This feature allows for voice command controls via compatible virtual assistants, adding an extra layer of convenience to everyday operations.

The thermostat is designed to be compatible with a variety of HVAC systems, including single-stage and multi-stage systems, ensuring broad applicability in many homes. Additionally, the device includes advanced sensors that monitor temperature and humidity levels to provide precise climate control, further enhancing energy efficiency and comfort.

Energy-saving features are a significant highlight of the SYSTXBBUIZ01. The thermostat is equipped with adaptive recovery technology, which learns the heating and cooling patterns of the home, allowing it to optimize operation schedules for maximum efficiency. Additionally, it includes features like geofencing, which adjusts the temperature based on the homeowner’s location, further promoting energy conservation.

The Bryant SYSTXBBUIZ01 stands out as a resilient and effective solution for modern home climate control, combining user-friendly design, smart functionalities, and energy-saving technologies. Its advanced features make it an ideal choice for anyone looking to enhance their home’s comfort and efficiency.