Ultimate 106 – Edition 1 – Issue 3 - 18.12.02 – 5129

Only 2 wires are connected to terminals 2 and 5. Leave the 2 wires that are not used coiled up neatly in the back of the socket for future use.

Plastic wire grip

Pull the plastic wire grip tight, trapping the wire.

Finally, fit the front plate onto the backbox with the screws provided.

IMPORTANT

Please note, cable supplied may not match

exactly the colours specified.

Please ensure that the 2 wires used at the extension socket are the same 2 wires used at the Ultimate 106 connectors.

2 Connect the extension sockets to the Ultimate 106

Remove the lower cover from the Ultimate 106.

 

 

 

 

 

Power

 

 

 

 

 

 

In Use

 

 

 

 

 

 

Day/Night Mode

 

 

 

 

 

 

Messages

 

 

 

 

Call Director/Answer Machine

 

12v/

12v/

 

Ext 11

Ext12

Ext13 Ext14 Ext15 Ext16

 

Com N.O. N.C.

 

 

 

Doorlock/

Telephone

 

 

External Music On Hold Input Normal

Program

 

Intercom

Line

EXT 11

EXT 12

EXT 13 EXT 14 EXT 15 EXT 16

 

Ultimate 106

There are 6 sets of twin screw connectors.

The telephone extension cable contains 4 strands of wire, 2 with broad orange or blue stripes, 2 with narrow orange or blue stripes.

IMPORTANT

If you have connected the 2 blue strands to the socket, you must also connect the blue strands to the twin screw connectors in the Ultimate 106.

Equally, if you have connected the 2 orange

strands to the extension socket, you must connect the 2 orange strands to the twin screw connector.

Strip the insulation cable off at the end in order to expose 5mm of copper wire for the blue or orange strands.

7

Page 9
Image 9
BT 106 manual Connect the extension sockets to the Ultimate, Remove the lower cover from the Ultimate