Bunn 40410.0000G Programming - Smart Wave With Display, Advanced Set-Up, Technician Set-Up

Models: 40410.0000G

1 20
Download 20 pages 26.06 Kb
Page 11
Image 11

PROGRAMMING - SMART WAVE WITH DISPLAY

BREW VOLUME SET-UP:

NOTE: Maximum water on time is 5 minutes.

1.Press the "HIDDEN" switch until display reads A1. This represents the adjust mode "Brew Time" for the "A" brew switch. The display will then change to (minutes-seconds). Press "BREW A" to decrease time (-) or "BREW B" to increase time (+).

2.Press and release "HIDDEN" switch until display reads A2. This represents the adjust mode "Brew Meter" (Pulse Brew) for the "A" brew switch. The display will then change to (1-14). Brewer has 14 preset pulse brew routines to choose from. Factory default is 1. With 14 being the maximum time. Press "BREW A" to decrease (-) or "BREW B" to increase (+).

3.Press and release "HIDDEN" switch until display reads A3. This represents the adjust mode "Drip Out Time" for the "A" brew switch. The display will then change to (minutes-seconds). Press "BREW A" to decrease time (-) or "BREW B" to increase time (+).

4.Repeat steps 1 -3 for setting the "B" brew switch.

 

Adjustment

Default

Min.

Max.

Increments

A1

= Brew switch "A" Brew time

2:05

0:26

5:00

1 second

A2

= Brew switch "A" Brew meter

1

1

14

1

A3

= Brew switch "A" Drip out time

1:00

0:05

5:00

5 seconds

B1

= Brew switch "B" Brew time

2:05

0:26

5:00

1 second

B2

= Brew switch "B" Brew meter

1

1

14

1

B3

= Brew switch "B" Drip out time

1:00

0:05

5:00

5 seconds

ADVANCED SET-UP:

Press the "HIDDEN" switch until display reads P1. This represents the advanced adjust modes .

 

Adjustment

Default

Min.

Max.

Increments

P1

= Temperature set

200°F

185°F

205°F

1

Degree

P2

= Ready Temperature

195°F

180°F

198°F

1

Degree

P3

= Brew Count (Display Only)

0

0

9999

1

Brew Cycle

P4

= °F or °C

°F

N/A

N/A

N/A

TECHNICIAN SET-UP:

Press the "HIDDEN" switch until display reads U1. This represents the Technician adjust modes .

 

Adjustment

Default

Min.

Max.

Increments

U1

= Display Water Level Threshhold

< 10

0

255

1

U2

= Adjust Water Level Threshhold

85

30

220

1

U3

- U7 FACTORY ADJUSTMENTS

 

DO NOT

ADJUST

 

U8

= Calibrate Temperature Sensor

200°F

190°F

210°F

1°

Restore Factory Defaults:

Press the "ENABLE BREW ON/OFF" switch while applying AC power. Continue pressing the "ENABLE BREW ON/ OFF" switch for 10 seconds. During that 10 seconds the middle bars on the display will be on. After 10 Seconds the the 3 upper, middle and lower bars on the display will be lit for 5 seconds. During that 5 seconds, release and again press the "ENABLE BREW ON/OFF" switch to restore default settings – the display will show “DONE”.

Note: The Restore process cannot be done when Dip Switch # 1 is On (Program Lockout).

Page 11

40410

092211

 

Page 11
Image 11
Bunn 40410.0000G Programming - Smart Wave With Display, Advanced Set-Up, Technician Set-Up, U7 FACTORY ADJUSTMENTS, Do Not