PROGRAMMING - SILVER SERIES
BREW VOLUME SET-UP:
NOTE: Set small and large batches separately. Maximum water on time is 5 minutes. Use the following steps when the setting is unknown.
1.Place an empty funnel in the funnel rails and an empty server beneath the funnel.
2.Press the "ENABLE BREW ON/OFF" switch ("ON").
3.Press and hold the small brew start switch until the LED indicator alternately flashes red/green (approximately 15 seconds). Release the switch.
4.Allow the cycle to continue until the desired amount of water is dispensed and then press the "ENABLE BREW ON/OFF" to turn "OFF" the brewer.
The brewer is now set to dispense this amount of water for each subsequent small brew cycle.
To increase the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty server beneath the funnel. Press the "ENABLE BREW ON/OFF" switch (ON). Press and hold the small "BREW" switch until you hear the solenoid click
To decrease the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty server beneath the funnel. Press the "ON/OFF" switch (ON). Momentarily press and release the small "BREW" switch once for each ounce (approximate) of water to be removed from the existing setting. Press and hold the small "BREW" switch until you hear the solenoid click
NOTE: Repeat the steps above to set the large batch by using the large brew switch as desired.
OPTIONAL PULSE BREW SET-UP:
NOTE: Set small and large batches separately. Brewer has 4 preset pulse brew routines to choose from. Factory default is 1. With 4 being the maximum time.
With the machine off, press the small or large switch for 10 seconds. Red LED will flash to indicate current setting ( 1 – 4 ). Press same switch the number of times ( 1 – 4 ) for the desired setting. If the switch is pressed more than 4 times, the setting will remain at 4. After 5 seconds the red Led will resume flashing the selected number. When no switches are pressed for 30 seconds, the mode will exit. Or the mode may be exited by pressing the "ENABLE BREW ON/OFF" switch. Repeat above procedure with the other brew switch.
Restore Factory Defaults:
Press the "ENABLE BREW ON/OFF" switch while applying AC power. Continue pressing the "ENABLE BREW ON/ OFF" switch for 10 seconds. During that 10 seconds, the red LED will be on steady. After 10 seconds the green LED will begin flashing rapidly for 5 seconds. During that 5 seconds, release and again momentarily press the "ENABLE BREW ON/OFF" switch again to restore default settings. The Led will alternate rapidly Red and Green for a few seconds indicating the restore has been accomplished.
Note: The Restore process cannot be done when Dip Switch # 1 is On (Program Lockout)
Page 9 | 40410 | 092407 |
|