SERVICE (cont.)
AUGER DRIVE MOTOR
P1922 |
FIG. 4 AUGER MOTOR |
Location:
The auger motor is located on the right rear of the motor assembly mounting panel.
Test procedures:
1.Disconnect the dispenser from the power source.
2.Check the voltage across the positive (red wire) terminal and the negative (black wire) terminal on the auger motor with a voltmeter. With the dispenser door open and the product level in the CDS hopper lower than the probe, press and hold the SERVICE switch. Connect the dispenser to the power supply. The indication must be 4.0 to 26.5 volts dc.
If voltage is present as described, the auger mo- tor drive is operating properly. If auger does not turn, replace the auger motor.
If voltage is not present as described, refer to wiring diagrams and check wiring harness.
Removal and Replacement:
1.Remove hopper assembly and set aside for reas- sembly.
2.Remove six
3.Remove the four
motor mounting bracket and auger motor to the rear of the auger motor mounting panel.
4 Disconnect the wires from the auger drive motor.
5.Remove the auger motor mounting bracket, auger motor and dust seal as an assembly.
6.Remove the dust seal from the auger motor and discard the motor.
7.Install dust seal on the new auger motor shaft and align the notch in the seal with the motor casting.
8.Connect the wires from the auger motor to the terminals in the main wiring harness. See Fig. 5.
9.Using four
10.Install the hopper assembly.
11.Install the rear cover with six
RED to Control
Board
BLK to GRN Wire
Main Harness to
Control Board
P1902
FIG. 5 AUGER MOTOR TERMINALS