TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Powder | 1. No water | Water lines and valves to the dis- |
product |
| penser must be open and free of |
|
| obstructions. |
| 2. No power or incorrect voltage to | Check that the power cord is con- |
| the dispenser. | nected to the CDS dispenser and for |
|
| voltage from the CDS dispenser. |
| 3. Dispense Solenoid Valve | Refer to Service- Dispense Solenoid |
|
| Valve for testing procedures. See |
|
| page 32 |
| 4. Control Board and Probe | Refer to Service- Control Board and |
|
| Probe for testing procedures. See |
|
| page 18 |
| 5. Auger Drive | Refer to Service- Auger Drive for |
|
| testing procedures. See page 13 |
| 6. Transformer | Refer to Service- Transformer for |
|
| testing procedures. See page 26 |
| 7. Water Strainer (Optional) | A) Direction of flow arrow must be |
|
| pointing towards dispenser. |
|
| B) Remove the strainer and check for |
|
| obstructions. Clear or replace. |
Dripping from dispense tip | 1. Dispense Solenoid Valve | Remove dispense valve and clear any |
|
| obstructions. Rebuild or replace the |
|
| valve if necessary. See page 32 |
Water flows continuously | 1. Control Board and Probe | Refer to Service- Control Board and |
|
| Probe for testing procedures. See |
|
| page 18 |
| 2. Dispense Solenoid Valve | Refer to Service- Dispense Solenoid |
|
| Valve for testing procedures. See |
|
| page 32 |
10 | 29793 061599 |
|