TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Powder Auto-Fill will not dispense

1. No water

Water lines and valves to the dis-

product

 

penser must be open and free of

 

 

obstructions.

 

2. No power or incorrect voltage to

Check that the power cord is con-

 

the dispenser.

nected to the CDS dispenser and for

 

 

voltage from the CDS dispenser.

 

3. Dispense Solenoid Valve

Refer to Service- Dispense Solenoid

 

 

Valve for testing procedures. See

 

 

page 32

 

4. Control Board and Probe

Refer to Service- Control Board and

 

 

Probe for testing procedures. See

 

 

page 18

 

5. Auger Drive

Refer to Service- Auger Drive for

 

 

testing procedures. See page 13

 

6. Transformer

Refer to Service- Transformer for

 

 

testing procedures. See page 26

 

7. Water Strainer (Optional)

A) Direction of flow arrow must be

 

 

pointing towards dispenser.

 

 

B) Remove the strainer and check for

 

 

obstructions. Clear or replace.

Dripping from dispense tip

1. Dispense Solenoid Valve

Remove dispense valve and clear any

 

 

obstructions. Rebuild or replace the

 

 

valve if necessary. See page 32

Water flows continuously

1. Control Board and Probe

Refer to Service- Control Board and

 

 

Probe for testing procedures. See

 

 

page 18

 

2. Dispense Solenoid Valve

Refer to Service- Dispense Solenoid

 

 

Valve for testing procedures. See

 

 

page 32

10