Bunn CDS-3 manual TROUBLESHOOTING cont PROBLEM, Remedy, Probable Cause

Models: CDS-3

1 34
Download 34 pages 40.35 Kb
Page 9
Image 9

TROUBLESHOOTING (cont.)

PROBLEM

Product level in CDS is lower than level Probe - CDS running; Powder Auto-Fill door lamp flashes two times

PROBABLE CAUSE

1.Powder Auto-Fill not pulled com- pletely forward.

2.CDS level probe misaligned.

REMEDY

1.Check that the Powder Auto-Fill is pulled completely forward until the guide rails roll into the indented position.

2.Position the CDS level probe so that it is located in the notch of the CDS hopper and touching the contact protruding from the front of the CDS cooling drum mount.

Product level in CDS is lower than level Probe - CDS running; Powder Auto-Fill door lamp flashes three times

Product level in CDS is lower than level Probe - CDS running; Powder Auto-Fill door lamp flashes four times

The CDS product tastes “watery” or “sugary”

Powder Auto-Fill dispenses dry product only - dry powder build-up in mixing and whipper chambers

1.Powder Auto-Fill hopper not installed.

2.Powder Auto-Fill hopper not in- stalled properly.

1.Refill time exceeded five min- utes.

1.Improper adjustment of product mix ratio.

1.Powder Auto-Fill not connected to water source.

2.Water source turned off.

3.Water line obstructed.

1.Install the Powder Auto-Fill hop- per.

2.Reposition the Powder Auto-Fill hopper.

Check that the SERVICE switch is released or reset by opening and closing the Powder Auto-Fill door.

Adjust the product mix ratio per instructions in Powder Auto-Fill Adjustment. See page 5.

1.Connect the Powder Auto-Fill to a

20to 90 psi (138 to 620 kPa)water source.

2.Turn water source on.

3.Remove obstruction.

9

29793 011500

 

Page 9
Image 9
Bunn CDS-3 manual TROUBLESHOOTING cont PROBLEM, Remedy, Probable Cause