FAULT LIST

 

 

Door Lamp

Fault

 

 

ON

Normal operation - Powder Auto-Fill ready to

 

dispense

 

 

Flashes ON/OFF at 50% duty cycle

Low product level in Powder Auto-Fill hopper

 

 

Two flashes about every 2 seconds

CDS/Powder Auto-Fill probe circuit open

 

 

Three flashes about every 2 seconds

Powder Auto-Fill hopper not in place

 

 

Four flashes about every 2 seconds

CDS refill exceeded 5 minutes

 

 

OFF

Door not closed

 

 

 

 