Bunn JDF-4S service manual Troubleshooting, Problem, Probable Cause, Remedy

Models: JDF-4S

1 31
Download 31 pages 40.19 Kb
Page 20
Image 20

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

All electronic components have 120-240 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the application of external voltages may result in board failure.

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a terminal or crimp.

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water.

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help to avoid twists and kinks in the tubing.

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

WARNING – • Exercise extreme caution when servicing electrical equipment.

Unplug the dispenser when servicing, except when electrical tests are specified.

Follow recommended service procedures.

Replace all protective shields or safety notices.

PROBLEM

Cold Water Circulation Dispense stations not working. Note: Cooling failure or excessive cabinet temperatures for more than 4 hours will result in dispense lockout or no dispense.

Note: Reset fault/timer by unplug- ging unit.

Dispense nozzle dripping/won't stop dispensing.

PROBABLE CAUSE

1.Cabinet cooling fan.

2.Bath recirculation pump.

3.Restricted water flow to cabinet water coil and bath.

1.Juice residue causing oring on dispense nozzle to lose vacuum.

2.Mechanical Switch Models- This may be caused by juice residue splashed or wiped onto switches.

3.Membrane Switch Models-

REMEDY

Replace fan (24vdc).

Note: Fan receives power when the dispenser is powered.

A)If not running, check refrigera- tion switch and wiring for proper continuity.

B)Check for 120V or 230V AC at pump. Replace pump.

Check for kinked hose.

A)Remove dispense nozzle. Clean nozzles and oring in mild detergent solution.

B)Use soft bristle brush and mild detergent solution to clean dispense valve area that dispense nozzles are seated.

Clean or replace switches.

Check continuity of dispense switches. Replace as needed.