Bunn JDF-4S Function List, Circuit Board LED Indicators - JDF-2SEarly Models, Led #, LED Color

Models: JDF-4S

1 31
Download 31 pages 40.19 Kb
Page 18
Image 18
FUNCTION LIST

FUNCTION LIST

Circuit Board LED Indicators - JDF-2S (Early Models)

LED #

LED Color

Illuminates:

 

 

 

1

Green

When the compressor should be ON.

 

 

 

2 Cabinet

Red

When the cabinet temperature is above 50 degrees F.

 

 

 

 

 

Flashes slowly when cabinet temperature exceeds 50 degrees F for 4

 

 

hours. Dispense functions are locked out under this condition. Power

 

 

down the dispenser to reset.

 

 

 

 

 

Flashes rapidly if dispense is attempted in lockout condition.

 

 

 

 

 

Open cabinet thermistor circuit will flash #2 and #3 LED’s 1 time every 3

 

 

seconds.

 

 

 

 

 

Shorted cabinet thermistor will turn #2 and #3 LED’s on steady.

 

 

*This mode disables the cabinet low temperature lockout fault.

3 Cabinet

Green

When cabinet temperature is below 50 degrees F.

 

 

 

4 Bath

Red

When bath temperature is above 34 degrees F.

 

 

 

 

 

Flashes slowly when compressor is in a 6 minute delay period.

 

 

 

 

 

Open bath thermistor circuit will flash #4 and #5 LED’s 1 time every 3

 

 

seconds. The compressor will not run under this condition.

 

 

 

 

 

Shorted bath thermistor circuit will flash #4 and #5 LED’s 2 times every 3

 

 

seconds. The compressor will not run under this condition.

 

 

 

5 Bath

Green

When bath temperature is below 34 degrees F.

 

 

 

 

1

2

3

4

5

FIG 18 JDF-2S

P3585

(Early Models)

 

18

44744.2 110813

 

Page 18
Image 18
Bunn JDF-4S service manual Function List, Circuit Board LED Indicators - JDF-2SEarly Models, Led #, LED Color, Illuminates