Bunn JDF-4S OPERATING CONTROLS Continued, Product Dispense Switch Membrane Switch Machines

Models: JDF-4S

1 31
Download 31 pages 40.19 Kb
Page 9
Image 9
OPERATING CONTROLS (Continued)

OPERATING CONTROLS (Continued)

Product Dispense Switch (Membrane Switch Machines)

A.Product Dispense Switch

Momentarily pressing and releasing one of the switches will initiate a timed dispense. Each station has three different timed dispenses which are preset at the factory. Refer to DISPENSER USE section for preset volumes and adjustment procedures.

B.Plus/Stop Switch

This switch can be used to “top-off” a beverage. Pressing and holding switch will initiate product flow from the respective nozzle; releasing the switch will stop the flow. Momentarily pressing this switch during a timed dispense will stop the flow.

C.Chilled Water Dispense Switch (Optional for JDF-4S only)

Pressing and holding switch will initiate chilled water flow from the nozzle; releasing the switch will stop flow.

FIG 11 Product Dispense Switches - JDF-2S

FIG 12 Product Dispense Switches - JDF-4S

Dispense Lockout Switch

This switch is located at the bottom front of the dis- penser just behind the drip tray. It is used to turn ON and OFF the Dispensing function. It is also used for some programming and fill procedures.

FIG 13 Dispense Lockout Switch

Program Switch

This switch is located near the main control board next to the refrigeration switch.

FIG 14 Program Switch

9

44744.2 110813

 

Page 9
Image 9
Bunn JDF-4S OPERATING CONTROLS Continued, Product Dispense Switch Membrane Switch Machines, Dispense Lockout Switch