PROGRAMMING THE DISPENSER (Cont.)

Program Mode: Used to change or enter new set-up values.

To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will display “__PPP” to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use the Increase (+) and Decrease (-) switch to adjust the values.

LED DISPLAY

0180

130

2

0. 0

3

0. 0

4

0. 0

XX.X

PROGRAM MODE

DESCRIPTION

Tank Temperature

Default = 180°F (82°C)

 

Range = 120° - 200°F (49 - 93°C)

 

Ready Temp = Tank Temp minus 10°F

 

(~5.5°C)

Dispense Ratio

Set Coffee Mix Ratio

 

Default = 30:1

 

Range = 20 Max / 100 Min

Portion Volume

Set Portion Dispense Volume

 

Default = 0.0, Disabled

 

Range = 16.0 / 40.0 Oz.

 

(0.5 / 1.2 L)

Dispense Total

Hold Decrease Switch to Reset Total

 

to Zero. 0.0 Gal (0.0 L)

Rinse Alarm Timer

Default = OFF (Rinse Alarm Disabled)

 

Range = 8 - 24 hrs

Software Version

Displays Software Version # -

 

Exits To Home View After 3 Seconds.

13

44806.1 081211

 

Page 13
Image 13
Bunn LCA-1, LCR-1 service manual Programming the Dispenser, Program Mode Description