PROGRAMMING THE DISPENSER (Cont.)
Program Mode: Used to change or enter new
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position, the unit will display “__PPP” to indicate it is in the Program Mode. Use the MENU switch to scroll to the next display. Use the Increase (+) and Decrease
LED DISPLAY
0180
130
2 | 0. 0 |
3 | 0. 0 |
4 | 0. 0 |
XX.X
PROGRAM MODE | DESCRIPTION |
Tank Temperature | Default = 180°F (82°C) |
| Range = 120° - 200°F (49 - 93°C) |
| Ready Temp = Tank Temp minus 10°F |
| (~5.5°C) |
Dispense Ratio | Set Coffee Mix Ratio |
| Default = 30:1 |
| Range = 20 Max / 100 Min |
Portion Volume | Set Portion Dispense Volume |
| Default = 0.0, Disabled |
| Range = 16.0 / 40.0 Oz. |
| (0.5 / 1.2 L) |
Dispense Total | Hold Decrease Switch to Reset Total |
| to Zero. 0.0 Gal (0.0 L) |
Rinse Alarm Timer | Default = OFF (Rinse Alarm Disabled) |
| Range = 8 - 24 hrs |
Software Version | Displays Software Version # - |
| Exits To Home View After 3 Seconds. |
13 | 44806.1 081211 |
|