CALIBRATING THE DISPENSER
NOTE: The
LED DISPLAY
1 r un
1 | 2 2 |
2 | r u n |
2 | 7 6 0 |
3 | 4 0 |
4 | En g |
5 | E _ _ |
CALIBRATION MODE | DESCRIPTION |
Pump Cal. Procedure | Set |
| to PRIME position. Place Graduated |
| Cylinder under dispense tip. Press and |
| hold Dispense Switch until pump stops |
| (20 sec) Refer to Calibration Procedure. |
Pump Cal. # | Enter mL collected from the 20 sec. |
| test above. |
| Default = 22 |
| Range = 18 - 26mL |
Water Flow Rate | Set |
| to RINSE position. Place Graduated |
| Cylinder under dispense tip. Press and |
| hold Dispense Switch until pump stops |
| (20 sec) Refer to Calibration Procedure. |
Water Flow Rate | Enter mL collected from the 20 sec. |
| test above. |
| Default = 760 |
| Range = 780 - 820 mLiters |
Cabinet Temperature | |
| Cabinet Temperature |
| Default = 40°F (4°C) |
| Range = 35°F - 75°F (2° - 24°C) |
English or Metric Mode | Used to select the desired units. |
| Default = English |
| S.I. for Metric |
Error Code Memory | Display cycles through the last (3) |
| Error Codes. |
| Erase by holding the Decrease |
| switches for 10 sec. |
| Currently have to hold (+) & |
17 | 44806.1 081211 |
|