PROGRAMMING (Continued)

LCD DISPLAY

TANK TEMP 190 (-) EXIT (+)

READY TEMP 180

(-) EXIT (+)

CABINET TEMP 38

(-) EXIT (+)

ACTION

Use the (+) or (-) buttons to adjust the target Temp.

Use the (+) or (-) buttons to adjust the target Temp.

Use the (+) or (-) buttons to adjust the target Temp.

DESCRIPTION

Sets the water Tank temperature: (120 - 200°F) or (49 - 93°C)

Sets the hot water Ready temperature: Typically set to the min. desired dispense temp.

Sets the Chilled cabinet target temperature: (38 - 50°F) or (3 - 10°C)

The following functions can be Password Protected. If you wish to prevent others from accessing these functions, enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these functions in the future.

LCD DISPLAY

ACTION

DESCRIPTION

ENTER PASSWORD

(-) 0 (+)

SET PASSWORD ?

(-) 0 (+)

2 OR 3 PRODUCTS?

(2)EXIT (3)

 

 

 

 

SELECT UNITS

 

 

 

 

ENG

EXIT METRIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERATION ?

 

If ON

ON

EXIT

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

DEICE CYCLE TIME

 

 

 

 

(-)

120 MIN (+)

 

 

 

 

 

 

 

 

 

 

If NO

RINSE ALARM ?

NO

EXIT

YES

 

If YES

 

 

 

 

 

 

 

 

 

 

 

RINSE TIME ?

 

 

 

 

(-)

12 HRS

(+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RINSE LOCKOUT ?

 

 

 

 

NO

EXIT

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to Next Page

Use the (+) or (-) buttons to enter password.

Use the (+) or (-) buttons to change the password.

Select the number of products to be dispensed

Select the preferred units.

Select OFF to disable the Refrigeration system

Select the time delay between automatic deicing of the cabinet

Select (YES) or (NO)

Use the (+) or (-) buttons to adjust Rinse Alarm delay.

Select (YES) to enable

Enter the access Code to view the remaining functions. Factory Default = 0.

Enter your own Code to prevent access to the remaining functions. [0 to 9999]

Used to switch from standard 3 products to 2 products w/Autoswitching of the Left and Middle Bibs.

Used to select the preferred units of measurement. (Oz., Gal, deg F) or (mL, L, deg C)

Select OFF to temporarily override a cooling system fault and allow the machine to dispense coffee.

If ice builds up on the evaporator - decrease the delay. If the cabinet is not cold enough - increase the delay.

Factory Default=120 (2 hrs)[min=30, max=180]

Selecting Yes will enable the Rinse Alarm function, (see Rinse Alarm)

Enter the desired time between required Rinse Cycles in hours. [8 to 24 hrs]

Select YES to Lockout dispensing until the Rinse Alarm has been cleared. Default is NO.

13