REPLACING THE PUMP TUBING
The pumps and tubing used in this dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed beverage.
Refer to the Tube Replacement Instruction on the Cabinet door for details.
1.Rinse the pump tubing with warm tap water (Refer to step 5 of the Weekly Sanitizing instructions) prior to removing the tubes to avoid concentrate spills.
2.Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set the retainer plate aside.
3.Depress the tension screw and remove it from the notch in the pump housing, releasing the tube compression band.
4.Open the compression band and gently pull the pump tube from around the pump’s rotor.
5.Inspect the pump bands for signs of cracking or excessive wear. Replace if necessary.
6.Apply lubricant
7.Insert the tube onto the mix chamber port, then wrap the new tubing around the pump rotor, making sure the elbow and clamps end up on the bottom side of the pump housing.
8.Depress the tension screw and insert it in the notch in the pump body, reapplying spring tension to the compression band.
9.Replace the tubing retainer plate and tighten the thumbscrew.
10.Repeat steps 1 through 9 for the other two pumps.
Note: Replacement Tube/Adapter Kits can be purchased from
Thumbscrew |
|
|
|
|
|
|
|
|
|
|
|
|
|
Tension |
|
|
|
| 2.0” |
|
|
|
|
| 2.0” |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Screw |
| Lubricate between arrows | |||||||||||
|
| ||||||||||||
Remove Retaining Plate Release Spring Tension | Remove Tubing |
|
| Lubricate New Tube |
Tension Screw |
|
Tube Clamp |
|
Install New Tubing | Completed Installation |
20 | 41129 030910 |
|