PROGRAMMING (Continued)
LCD DISPLAY
XXOVERFLOW > 155
XXREFILL
WTR START DELAY
WTR STOP DELAY
TEST SWITCHES ? UseSwitchToTest
TEST REFILL ?
EXIT YES
TEST HEATER ?
EXIT YES
ENTER ASSET #
SERIAL #
LCR 0000000
VIEW FAULTS?
LATEST FAULT
NO FAULTS
FACTORY DEFAULTS
NO YES
ACTION | DESCRIPTION |
Use the (+) or | Used to set the Conductance Threshold for the |
adjust Overflow threshold | Tank Overflow Probe |
Use the (+) or | Used to set the Conductance Threshold for the |
adjust Refill threshold | Tank Refill Probe. |
Use the (+) or | Dispense Valve ON Delay. Eliminates weak mix |
adjust delay time | at the beginning of a dispense. |
Use the (+) or | Dispense Valve OFF Delay. Flushes the mix |
adjust delay time | chamber at the end of a dispense. |
NONE | Switch Diagnostic: Activate switches separately to |
| test. Display will indicate which Switch has been |
| activated. NOTE: Door Interlock switch must be |
| held closed. |
Momentarily depress (YES) | Refill Valve Diagnostic: Press YES to momentarily |
| energize the Solenoid. CAUTION: Inlet Valve will |
| open and water will flow, if connected and turned |
| ON. |
Momentarily depress (YES) | Tank Heater Diagnostic: Press YES to momentarily |
| energize the Tank Heater Circuit. CAUTION: AC |
| power will be applied to the Tank Heater Circuit. |
Use the (+) or | Allows the user the option of entering an Asset |
enter the ASSET NUMBER | Number. Default is 000000 |
NONE | Displays the manufacture’s Serial Number (should |
| be identical to the Serial Number on the Data |
| Plate) |
Select (+) to view the Fault | This unit stores the last 3 Fault Conditions in |
Conditions | memory for diagnostic purposes. |
Use the (+) or | Displays up to 3 FAULT Conditions or NO |
through the Faults | FAULTS, if nothing has failed since the last “Reset |
| Defaults”. |
Select (YES) or (NO) | CAUTION: Selecting YES will RESET all Program- |
| ming Functions to the Factory Default settings |