TROUBLESHOOTING (cont.) |
|
PROBLEM | PROBABLE CAUSE |
Water flows into tank continuously | 1. Brew Timer |
(ICED/OFF/HOT Switch in the "ICED | A) Iced Tea |
or "HOT" position) |
|
| B) Hot Tea |
REMEDY
Refer to Service - Brew Timer (Iced Tea) for testing procedures. See page 20
Refer to Service- Brew Timer (Hot Tea) for testing procedures. See page 17
Water flows into tank continuously | 1. Brew Solenoid Valve | Refer to Service - Brew Solenoid |
(ICED/OFF/HOT Switch in the "OFF" | A) Iced Tea | |
position) |
| Valve (Iced Tea) for testing proce- |
|
| dures. See page 16 |
| B) Hot Tea | Refer to Service- Brew Solenoid |
|
| Valve (Hot Tea) for testing proce- |
|
| dures. See page 15 |
Beverage overflows dispenser | 1.Dispenser | The dispenser must be completely |
|
| empty before starting a brew cycle. |
| 2. Brew Timer | Refer to Service - Brew Timer (Iced |
| A) Iced Tea | |
|
| Tea) for testing procedures. See |
|
| page 20 or 21 |
| B) Hot Tea | Refer to Service- Brew Timer (Hot |
|
| Tea) for testing procedures. See |
|
| page 17 or 18 |
| 3. Brew Solenoid Valve | Remove the Iced Tea Brew Solenoid |
| A) Iced Tea | |
|
| Valve and clean any obstruction. |
|
| Rebuild or replace the valve if nec- |
|
| essary. See page 16 |
| B) Hot Tea | Remove the Hot Tea Brew Solenoid |
|
| Valve and clean any obstruction. |
|
| Rebuild or replace the valve if nec- |
|
| essary. See page 15 |
| 4. Dilution Solenoid Valve | Refer to Service - Dilution Solenoid |
|
| Valve for testing procedures. See |
|
| page 24 |
Page 12
28201 081500