Bunn TNTF-3 service manual Tank Heater, SERVICE cont, Disconnect the brewer from the power supply

Models: TNTF-3

1 30
Download 30 pages 36.83 Kb
Page 28
Image 28
TANK HEATER

SERVICE (cont.)

TANK HEATER

FIG. 24 TANK HEATER

P2213.60

 

Location:

The tank heater is located inside the tank and se- cured to the tank lid.

Test Procedures:

1.

Disconnect the brewer from the power supply.

2.

With a voltmeter, check the voltage across the

 

black and white wires on 120 volt models or the

 

black and red wires for 120/208 volt models with

 

a voltmeter. Connect the brew to the power source.

 

The indication must be:

Removal and Replacement:

1.Disconnect the black wire and the white or red wire from the tank heater terminals.

2.Remove sprayhead and the hex nut securing the sprayhead tube to the hood. Set aside for reas- sembly.

3.Disconnect vent tube.

4.Remove the six #10 thread cutting screws secur- ing the tank lid to the tank.

5.Remove the tank lid with limit thermostat, spray- head tube, tank heater and vent tube.

6.Remove the two hex nuts securing the tank heater to the tank lid. Remove tank heater with gaskets and discard.

7.Install new tank heater with gaskets on the tank lid and secure with two hex nuts.

8.Install tank lid with limit thermostat, sprayhead tube, tank heater and vent tube using six #10 thread cutting screws.

9.Secure sprayhead tube to hood using a hex nut.

10.Install sprayhead.

11.Connect vent tube to fitting.

12.Reconnect the wires to the limit thermostat and tank heater. See limit thermostat section in this manual when reconnecting wires.

13.Refer to Fig.25 when reconnecting the tank heater wires.

a) 120 volts ac for two wire 120 volt models .

b) 208 volts ac for three wire120/208 volt mod-

BLK to Control

WHI to Power Cord (120V Models) RED to Terminal Block (120/208V

els.

3. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4

If voltage is not present as described, refer to the Wir- ing Diagrams and check wiring harness.

4.Disconnect the black wire and the white wire or red wire from the tank heater terminals.

5.Check for continuity across the tank heater termi- nals.

If continuity is present as described, reconnect the wires, the tank heater is operating properly.

Thermostat or Thermal Fuse

Models)

If continuity is not present as described, replace the tank heater.

NOTE- If the tank heater remains unable to heat, re- move and inspect heater for cracks in the sheath.

FIG. 25 TANK HEATER TERMINALS

P1369

 

 

 

Page 28

28201 081598

Page 28
Image 28
Bunn TNTF-3 service manual SERVICE cont, Disconnect the brewer from the power supply, Tank Heater Terminals