LAMP CORD CONNECTOR

ULTRA-2 shown

FIG. 47 LAMP CORD CONNECTOR Manual background Location:

The lamp cord connectors are located inside the center top of the auger motor covers.

Test Procedures:

1.Disconnect the dispenser from the power source.

2.Disconnect the plug on the dispenser main harness from the connector from the lamp cord connec- tor.

3.Connect the dispenser to the power source. Turnon power (I/O) switch. The indication must be approxi- mately 12.6 volts dc.

4.Disconnect the dispenser from the power source. If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the Wiring Diagram and check the dispenser main wiring harness.

NOTE: Lamp cord assembly (Fig. 47) and lamps, must be tested and determined to be functioning properly before proceeding to step 5.

5.Check for continuity across the black wire pin and red wire pin of the lamp cord connector (Fig. 48). Continuity must be present when the lamp cord assembly is connected and must not be present when lamp cord assembly is disconnected from lamp cord connector.

If continuity is not present when lamp cord assembly is connected or continuity is present when lamp cord assembly is not connected, replace the lamp cord connector.

Removal and Replacement:

1.Disconnect the lamp cord assembly from the lamp cord connector.

2.Remove the two #8-32 locking screws securing the auger motor cover the auger motor bracket/cooling drum bracket. Move cover back far enough to gain access to the lamp cord connector.

3.Disconnect the lamp cord connector wires from the dispenser main wiring harness.

4.Remove nut and washer securing the lamp cord connector to the auger motor cover and discard nut, washer and lamp cord connector.

5.Remove new nut and washer from new lamp cord connector.

6.Push new lamp cord connector through the hole in the auger motor cover and secure with the new nut and washer.

7.Reconnect the wires on the cord connector to the dispenser main wiring harness.

8.Position auger motor cover on auger motor bracket/ cooling drum bracket and secure with two #8-32 locking screws.

9.Refer to Fig. 48 when reconnecting wires.

Manual backgroundManual background BLK to Main Wiring Harness

RED to Main Wiring Harness

FIG.48 LAMP CORD CONNECTOR