SERVICE (cont.)

SERVICE (cont.)

LAMP CORD ASSY

ULTRA-2 shown

FIG. 45 LAMP CORD ASSY

Location:

The lamp cord assembly is located in the top center of the auger motor cover.

Test Procedures:

7.Strip the wires from the lamp holder/socket as- sembly approximately .375”.

8.Using the two wire nuts, supplied, connect the new lamp cord assembly to the lamp holder/socket as- sembly wires.

9.Reinstall the hopper liner to the bottom of the hop- per cover.

10.Reinstall the hopper cover to the hopper.

11.Plug in the new lamp cord assembly to the lamp cord connector assembly on top of the auger mo- tor cover.

12.Refer to Fig. 46 when reconnecting the wires.

1.Disconnect the dispenser from the power source.

2.Unplug the lamp cord assembly from lamp cord connector assembly.

3.Check for continuity across the tip of the cord as- sembly and the housing. Continuity must not be present when both lamps are removed.

If continuity is present as described, the cord assembly is operating properly.

If continuity is not present as described, replace the cord assembly.

Removal and Replacement:

1.Disconnect the lamp cord assembly from the lamp cord connector assembly in the top of the auger motor cover.

2.Remove the hopper cover with the lamp cord as- sembly from the hopper.

3.Remove hopper cover liner from the hopper cover.

4.Cut the closed splice terminals connecting lamp cord assembly to the lamp holder/socket assembly off.

5.Remove lamp cord assembly from hopper cover and discard.

6.Push new lamp cord wires through the holes on the left outside top of the hopper cover.

FIG. 46 LAMP CORD WIRES

P1332