SERVICE (cont.)
CIRCUIT BREAKER
FIG. 11 CIRCUIT BREAKER |
Location:
The circuit breaker is located inside the dispenser on the front right frame post on
Test Procedures:
1.Disconnect the dispenser from the power source.
2.Remove the wires from the circuit breaker.
3.Check for continuity between the terminals. Conti- nuity must be present between the terminals.
If continuity is present as described the circuit breaker is functioning properly.
If continuity is not present as described, press the reset button and repeat step #3, if continuity is not present as described, replace the circuit breaker.
Removal and Replacement:
1.Remove the right side panel on
2.Remove the wires from the circuit breaker.
3.Compress the clips on the back side of the com- ponent bracket and gently push the circuit breaker through the opening in the bracket.
4.Push the new circuit breaker into the opening in the bracket until the clips snap into position.
5.Reconnect the wires to the circuit breaker.
6.Refer to Fig. 13 when reconnecting the wires.
FIG. 12 CIRCUIT BREAKER |
WHI/BLU from Transformer
WHI/YEL to Lamp Relay
RED to Lamp Relay
FIG. 13 CIRCUIT BREAKER TERMINALS
27 | 41084 102709 |
|