Small Office Remote Access Switch 55
IP R
OUTING
N
ETWORK
WITH
R
EMOTE
B
RIDGE
D
EVICES
Configure the CyberSWITCH
CONFIGURING THE SECURITY LEVEL
To begin, press 1 at the Security Menu, and the Security Level Menu will be displayed. To enable
Device Level Security , press 2.
CONFIGURING THE SYSTEM OPTIONS AND INFORMATION
The default configuration for System Option s is all security options enabled, which is accep table
for this network. No System Information or Administration Sessions are required. Theref ore, no
changes are necessary.
CONFIGURING THE DEVICE LEVEL DATABASES
Press 3 at the Security Menu, and the Device Level Database Menu will be displayed. To enable the
On-node Device Database, press 1 and follow the on-screen instructions.
To add the remote devices, press 2 (On-node Device entries). Press 1 to configure the information for
our first device, Monterey. You will be prompted for the device name, followe d by the Device Table
Menu:
Select 1, ISDN. The ISDN Menu will display the preconfigured default values:
We do not want to use the default ISDN Line Protocol of PPP. Press 1 to configure this device’s
ISDN line protocol. The device Monterey uses H DLC protocol, so we will press 2:
Device Name? Monterey
Device Table Menu: (Device = "Monterey")
1) ISDN
2) Frame Relay
3) X.25
4) Authentication
5) IP
6) IPX
7) AppleTalk
8) Bridging
9) POTS
10) Compression
Select function from above or <RET> for previous menu: 1
Device ISDN Menu: (Device = "Monterey")
1) ISDN Line Protocol “PPP (Point to Point Protocol)”
2) Base Data Rate “64000 bps”
3) Initial Data Rate “64000 bps”
4) Maximum Data Rate “128000 bps”
5) Dial Out Phone Number(s) “”
6) Subaddress “”
7) Profile Name “Default_Profile”
8) H0 Call Support DISABLED
Select function from above or <RET> for previous menu: 1