Alarm Configuration

7.Since the first sample taken can be misleading, you can use the selections in the Startup Alarm box to disable either the rising or the falling threshold for that sample only. If you would like to exclude the falling alarm, select the Rising option; the first sample taken will only generate a rising alarm, even if the sample value is at or below the falling threshold. To exclude the rising alarm, select the Falling option; the first sample will then only generate a falling alarm, even if the sample value is at or above the rising threshold. If you wish to receive both alarms as appropriate, select the Both option.

8.Use the selections in the Sample Type box to indicate whether you want your threshold values compared to the total count for the variable (Absolute), or to the difference between the count at the end of the current interval and the count at the end of the previous interval (Delta). Make sure you have set your thresholds accordingly.

9.Click in the Rising Threshold field; enter the high threshold value for this alarm.

10.There are two ways to assign an event to your rising threshold: click in the Rising Event Index text box and enter the number of the event you would like to see triggered if the rising threshold is crossed; or use the Events Watch list in the main Alarm/Event window to highlight the desired event, then click on the Rising Event Index button. Be sure you assign the number of a valid event or there will be no response if the selected variable meets or crosses this threshold; assigning an index of zero effectively disables the threshold, as there will be no indication that it has been crossed.

For more information on how events are triggered, see How Rising and Falling Thresholds Work, on page 3-28.

11.Click in the Falling Threshold field; enter the low threshold value for this alarm.

12.There are two ways to assign an event to your falling threshold: click in the Falling Event Index text box and enter the number of the event you would like to see triggered if the falling threshold is crossed; or use the Events Watch list in the main Alarm/Event window to highlight the desired event, then click on the Falling Event Index button. Again, be sure you assign the number of a valid event or there will be no response if the selected variable meets or crosses this threshold; assigning an index of zero effectively disables the threshold, as there will be no indication that it has been crossed.

For more information on how events are triggered, see How Rising and Falling Thresholds Work, on page 3-28.

NOTE

There is no limit to the number of alarms that may be assigned to the same event.

3-20

Advanced Alarm Configuration

Page 118
Image 118
Cabletron Systems 2000 manual Alarm Configuration

2000 specifications

Cabletron Systems was a prominent company in the networking and communications industry during the late 20th century, and by the year 2000, it had established itself as a leader in providing high-performance networking solutions. The company was known for its innovative approach to network architecture and its commitment to delivering reliable products that enabled seamless connectivity in various environments.

One of the primary features of Cabletron Systems in 2000 was its advanced networking technologies, including Local Area Network (LAN) and Wide Area Network (WAN) solutions. The company specialized in developing multi-layer switches that could efficiently manage traffic and deliver high-speed data transfer. Their products were particularly popular in enterprise settings, where network performance and reliability were paramount.

Cabletron's solutions included a range of products, from Ethernet switches to routers, which were designed with scalability and flexibility in mind. This allowed businesses to adapt their networks to accommodate growth, without the need for a complete overhaul of their infrastructure. The company’s Integrated Networking Architecture (INA) was a significant innovation during this period, enabling efficient communication and management of diverse network resources.

Another major characteristic of Cabletron Systems was its commitment to interoperability. The company’s products were designed to be compatible with several industry standards, ensuring that organizations could easily integrate Cabletron solutions into their existing networks. This focus on compatibility helped to foster collaboration among different devices and systems, further enhancing network efficiency.

Security was also a key feature of Cabletron’s offerings in 2000. With growing concerns about data breaches and unauthorized access, the company incorporated advanced security measures into its products. These features included robust authentication protocols, encryption options, and secure management interfaces, which helped safeguard sensitive data during transmission.

Customer support and service were paramount to Cabletron Systems' business model. The company provided extensive resources, including training and technical support, to ensure that customers could maximize the potential of their networking solutions. This dedication to customer satisfaction contributed significantly to Cabletron’s reputation in the marketplace.

In summary, Cabletron Systems in 2000 emerged as a frontrunner in the networking industry, characterized by its innovative technologies, commitment to interoperability, emphasis on security, and strong customer support. Their products and solutions were designed to empower businesses, helping them achieve greater efficiency, scalability, and reliability in their network operations.