The SmartSwitch 2000 Chassis View

TIP

WARNING

Note that, if you select the ConÞguration option available for a Fast Ethernet interface, an entirely different window will appear; see ConÞguring Fast Ethernet Ports on First Generation Devices, on page 2-33, or ConÞguring Ethernet Ports on Second Generation Devices, on page 2-38, for information on conÞguring these ports.

For standard Ethernet interfaces, Full Duplex should only be enabled on an interface that has a connection to a single destination address at the other end of the connection (i.e., it is not a segment with an attached repeater cascading the connection to multiple destination addresses).

Full Duplex mode disables the collision detection circuitry at the interface, so that both Transmit and Receive wires can be used simultaneously. With a single destination address at the other end of the connection (for example, if the connection was to a full duplex interface on another switching device, or if a single Þle server was connected to the full duplex switch port), this essentially doubles the available bandwidth from 10 Mbit/sec to 20 Mbit/sec. Note that the interface at the other end of the connection must also have Full Duplex enabled at the attached interface.

Full Duplex mode must be disabled if the interface is communicating with multiple destinations simultaneously (i.e., if a repeater is cascaded from the interface), since Ethernet relies on Collision Sense for proper operation.

Similarly, an FDDI Full Duplex connection must also only be run point-to-point between two supporting FDDI interfaces (e.g., another HSIM-F6), since the dual bandwidth is attained by running data on both primary and secondary paths simultaneously. Since Full Duplex overrides standard FDDI protocol (and eliminates ring redundancy), it will not operate in a ÒringÓ conÞguration, but only as a point-to-point high speed data trunk between hubs. Note that you must use Local Management to conÞgure your HSIM-F6 for Full Duplex operation prior to making physical connections. Refer to your Local Management Guide for more information.

Use the options in this window to select the desired mode:

Standard Mode

In Standard Mode, an interface can only either transmit or receive at any given time, and must wait for one activity to be completed before switching to the next activity (receive or transmit). In this mode, standard wire speeds (10 Mbps for Ethernet, 100 Mbps for FDDI) are available.

Full Duplex

In Full Duplex Mode, an interface can both receive and transmit packets at the same time, effectively doubling the available wire speed to 20 Mbps (for Ethernet) or 200 Mbps (for FDDI).

Be sure to click on the Apply button to set your changes; note that the interfaceÕs current mode can be determined by the Þeld selected in the window.

2-32

Managing the Hub

Page 54
Image 54
Cabletron Systems 2000 manual Standard Mode, Full Duplex

2000 specifications

Cabletron Systems was a prominent company in the networking and communications industry during the late 20th century, and by the year 2000, it had established itself as a leader in providing high-performance networking solutions. The company was known for its innovative approach to network architecture and its commitment to delivering reliable products that enabled seamless connectivity in various environments.

One of the primary features of Cabletron Systems in 2000 was its advanced networking technologies, including Local Area Network (LAN) and Wide Area Network (WAN) solutions. The company specialized in developing multi-layer switches that could efficiently manage traffic and deliver high-speed data transfer. Their products were particularly popular in enterprise settings, where network performance and reliability were paramount.

Cabletron's solutions included a range of products, from Ethernet switches to routers, which were designed with scalability and flexibility in mind. This allowed businesses to adapt their networks to accommodate growth, without the need for a complete overhaul of their infrastructure. The company’s Integrated Networking Architecture (INA) was a significant innovation during this period, enabling efficient communication and management of diverse network resources.

Another major characteristic of Cabletron Systems was its commitment to interoperability. The company’s products were designed to be compatible with several industry standards, ensuring that organizations could easily integrate Cabletron solutions into their existing networks. This focus on compatibility helped to foster collaboration among different devices and systems, further enhancing network efficiency.

Security was also a key feature of Cabletron’s offerings in 2000. With growing concerns about data breaches and unauthorized access, the company incorporated advanced security measures into its products. These features included robust authentication protocols, encryption options, and secure management interfaces, which helped safeguard sensitive data during transmission.

Customer support and service were paramount to Cabletron Systems' business model. The company provided extensive resources, including training and technical support, to ensure that customers could maximize the potential of their networking solutions. This dedication to customer satisfaction contributed significantly to Cabletron’s reputation in the marketplace.

In summary, Cabletron Systems in 2000 emerged as a frontrunner in the networking industry, characterized by its innovative technologies, commitment to interoperability, emphasis on security, and strong customer support. Their products and solutions were designed to empower businesses, helping them achieve greater efficiency, scalability, and reliability in their network operations.