Connecting the Token Ring Module to a Hub
Refer to the Hub manufacturer’s manual for specific cabling information for connecting workstations to the Hub.
To connect the Token Ring module to a UTP Hub, attach one end of a UTP cable to the Token Ring module’s RJ45 connector and connect the other end with the appropriate connector to any port except the Ring In or Ring Out ports on a UTP Hub. The Ring In/Ring Out ports are used for interconnecting Hubs. Refer to the example shown in Figure
Figure
2.4.2Shielded Twisted Pair
When using Shielded Twisted Pair cabling, refer to the following (this assumes patch cables that are no longer than 8 feet or 2.4 meters):
Table
Data Rate | Compatibility | Cable Type | Longest Lobea |
|
|
|
|
|
|
|
|
| IBM and IEEE |
|
|
4 Mbps | 802.5 Token | IBM Types 1 | 240 m (787 ft.) |
| Ring |
|
|
|
|
|
|
| IBM and IEEE |
|
|
16 Mbps | 802.5 Token | IBM Types 1 | 100 m (328 ft.) |
| Ring |
|
|
|
|
|
|
a. To assure compatibility with future LANs, the longest lobe should be limited to 100 meters.
Token Ring Switch Module User Guide | Page |