2.4.2Shielded Twisted Pair

Connecting the Token Ring Module to a Hub

Refer to the Hub manufacturer’s manual for specific cabling information for connecting workstations to the Hub.

To connect the Token Ring module to a UTP Hub, attach one end of a UTP cable to the Token Ring module’s RJ45 connector and connect the other end with the appropriate connector to any port except the Ring In or Ring Out ports on a UTP Hub. The Ring In/Ring Out ports are used for interconnecting Hubs. Refer to the example shown in Figure 2-1.

Figure 2-1 Connecting a Token Ring Module to a UTP Hub

2.4.2Shielded Twisted Pair

When using Shielded Twisted Pair cabling, refer to the following (this assumes patch cables that are no longer than 8 feet or 2.4 meters):

Table 2-2 Shielded Twisted Pair Cabling Specifications

Data Rate

Compatibility

Cable Type

Longest Lobea

 

 

 

 

 

 

 

 

 

IBM and IEEE

 

 

4 Mbps

802.5 Token

IBM Types 1

240 m (787 ft.)

 

Ring

 

 

 

 

 

 

 

IBM and IEEE

 

 

16 Mbps

802.5 Token

IBM Types 1

100 m (328 ft.)

 

Ring

 

 

 

 

 

 

a. To assure compatibility with future LANs, the longest lobe should be limited to 100 meters.