Cabletron Systems 3T02-04 manual Swapping A Module

Models: 3T02-04

1 52
Download 52 pages 2.24 Kb
Page 41
Image 41
6.3 SWAPPING A MODULE

Swapping a Module

6.3 SWAPPING A MODULE

When swapping identical modules, it is recommended that you remove power from the ATX. However, the module you are replacing must be taken offline first, as described below.

1.Take the module to be replaced offline, either by pressing the OFFLINE button on the module front panel, or by using the Local Console Manager offline command.

2.Remove power from the ATX.

3.Remove the network connections from the module. Note the ports to which the network connections attach.

4.Loosen the screws at each end of the front panel of the module to be replaced.

5.Remove the installed module by pulling gently but firmly on the ears at the ends of the module's front panel.

6.Gently slide the new module into the plastic guides in the module slot until it is completely inserted. Push the module firmly into place, as far as it will go, to fully engage the connectors at the back of the module with the backplane at the rear of the ATX chassis.

7.Tighten the screws on each side of the module’s front panel.

8.If you took the original module offline by pressing the OFFLINE button, the new Token Ring module will automatically come back on line when it is inserted in the slot.

9.If you used the LCM offline command to take the original module offline, you must use the online command to bring the new module online.

10.Check the module LED power-on sequence as described in Chapter 2, Connecting to the Network.

11.Make the connections to the network as described in Chapter 2.

Token Ring Switch Module User Guide

Page 6-3

Page 41
Image 41
Cabletron Systems 3T02-04 manual Swapping A Module