Cabletron Systems 3T02-04 manual Delete all static addresses

Models: 3T02-04

1 52
Download 52 pages 2.24 Kb
Page 40
Image 40
•Delete all static addresses

Chapter 6: Adding/Swapping Modules

If the module you are adding has a different number of ports than the module you are removing, before you can power cycle the ATX you must:

Delete all static addresses

Delete all ARP addresses and IP routing table entries

Delete all filters

1.Make sure the ATX is powered off.

2.Remove the network connections from the module you are going to replace.

3.Loosen the screws at each end of the front panel of the interface module you are going to replace.

4.Remove the installed interface module by pulling gently but firmly on the ears at the ends of the module's front panel.

5.Gently slide the new module into the plastic guides in the module slot until it is completely inserted. Push the module firmly into place, as far as it will go, to fully engage the connectors at the back of the module with the backplane at the rear of the ATX chassis.

6.Tighten the screws on each side of the Token Ring module front panel.

7.Power on the ATX, and check the module LED power-on sequence as described in Chapter 2, Connecting to the Network.

8.Make the connections to the network as described in Chapter 2.

Page 6-2

Token Ring Switch Module User Guide

Page 40
Image 40
Cabletron Systems 3T02-04 manual Delete all static addresses