Installing the 9Cx14 Chassis

Attaching 9C614 INB Terminator Modules

Two 9C614 INB Terminator Modules must be attached to the rear of the SmartSwitch 9000 chassis when Interface Modules that use the INB are inserted in the front of the chassis. These modules provide proper termination for the Internal Network Bus (INB).

The INB Terminator Modules are attached by following the steps below:

1.Remove the INB Terminator Modules from the shipping box. (Save the box and packing materials in the event the module must be reshipped.)

2.Hold the INB Terminator Module by the handle and line up the screws that extend from the module with the screw holes in one of the INB Termination Connectors on the rear of the SmartSwitch 9000 chassis (Figure 1-7).

3.Push the INB Terminator Module in gently until the frame of the module touches the frame of the chassis.

4.Tighten the screws on the INB Terminator Module.

5.Repeat steps 1–4 to attach the second INB Terminator Module.

NOTE

The INB Terminator Module is designed to fit in either INB Termination Connector on the SmartSwitch 9000 chassis. If the screws that extend from the module do not line up with the screw holes on the INB Connector, turn the module over.

1-14

Page 22
Image 22
Cabletron Systems 9000, 9C114 manual Attaching 9C614 INB Terminator Modules