Preparing and Installing the 9A426-02 Module

Figure 2-6. Attaching an APIM to a 9A426-02 Module

7.Press down gently on the APIM to lock its female connector into the 9A426-02 Module’s male connector.

8.Secure the APIM to the module: Use a Phillips-head screwdriver to attach four round-head screws to the four standoffs on the 9A426-02 Module.

9.Attach the 9A426-02 Module’s ATM-Port Retaining Plate (see next page).

NOTE

Steps 1 through 9 explain how to insert one APIM in the 9A426-02 Module. To insert a second APIM, repeat the same steps.

Attaching the 9A426-02 Module’s ATM-Port Retaining Plate

1.Place the module (component side up) on a non-conductive, flat surface. Position the module so that the module’s front (faceplate) is facing you.

2.Locate the area where the ATM-Port Retaining Plate attaches to the faceplate.

3.Place the ATM-Port Retaining Plate on the module (align the retaining plate’s securing holes with the module’s securing holes). Make sure the Retaining Plate’s faceplate (its smaller side) is flush with the module’s faceplate (see Figure 2-7).

4.Secure the retaining plate to the module: Use a Phillips-head screwdriver to attach two flathead mounting screws to the module.

2-8