4.4 Environment

CHAPTER 4: SPECIFICATIONS

Contact

Signal

 

 

 

 

6

N/A

 

 

7

Receive +

 

 

8

Receive -

 

 

4.4 Environment

Storage temperature:

-40°C minimum

 

85°C maximum

Operating temperature:

5°C minimum

 

40°C maximum

Operating humidity:

5% to 95% non-condensing

4.5Safety

This unit meets the safety requirements of UL 1950, CSA C22.2 No. 950, and EN 60950; the EMI requirements of FCC Class A and EN 55022 Class A; and the EMC requirements of EN 50082-1.

Note: It is the responsibility of the person who sells the system to which the BRIM will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions.