5.0 OPTIONS
NOTE: Ensure you return both pots to their original position after address selection is complete, otherwise the amplifier will change its volume level to the new pot positions!
5.2.4 To Activate CAI Address Selection Procedure
Briefly press the ENTER
Enter Switch
After briefly pressing the
Flashing of Power LED channel A indicates the tens,
Flashing of Power LED channel B indicates the units of the address.
For example: different address setting LED sequences:
Address | Power LED Channel A/ TENS | Power LED Channel B/ TENS |
|
|
|
01 (factory settings) | 0* flash | 1* flash then short pause |
|
|
|
25 | 2* flashes then short pause | 5* flashes then short pause |
|
|
|
These sequences are repeated for 30 seconds (timeout).Then the Power LEDs return to their normal function.
To change CAI address, turn the appropriate Volume Potentiometer to the required address (Volume Pot Ch A => TENS, Volume Pot Ch B => UNITS).
To adjust the address you can use the scale markings of the
potentiometers.You will find the digits 0,1,2,3,4,5,6,7,8,9 on the 10 scale
spacing .
The current selected address will be immediately displayed BUT not automati- cally stored or activated! After each turn of pot you have another 30 seconds to timeout.You can leave this procedure without saving the new address by briefly pressing the
3 seconds. This new address is stored in an EEPROM, which holds the informa- tion even if the amp is subsequently disconnected from mains. Be sure to set the
5.2.5 CAI Status Indicator
This green LED indicates the presence of communication between PC and the amp.
5.2.6Overview Or Remote Controls CAI CAI allows:
To control the
To mute each channel independently
(exception: mono modes, only channel A is affected)
To switch the VORTEX into STANDBY mode (and back again)
To monitor temperature,
P.22 | CAMCO USER MANUAL |
VORTEX POWER AMP SERIES |