4.0 OPERATION

4.7 Fans

The fans mounted in the VORTEX operate permanently, but as long as the temperature remains below 40 °C they run at their slowest speed and can hardly be heard. The highest detected temperature from either channel controls the speed of the fans: above 40 °C the speed is increased until it reaches its maximum value.

4.8 Filter Cleaning

A removable filter system is provided on the air intakes to the cooling system. If the filter becomes clogged, the unit will not cool as efficiently as it should and may produce output levels that are lower than normal due to high heat sink temperatures.

To clean, gently slide the whole plastic filter assembly to the left and release from the front panel. Carefully unclip the outer moulding to reveal the filter. Clean the filter with a mild dishwashing detergent and warm water. Once dry, insert the filter back into the cradle and cover with the surround moulding. Slide the whole assembly to the right to secure onto the front panel.

Spare filter assembly’s may be ordered from your dealer.

3

4

5

VORTEX Filter Assembly

1 Clip Apertures

2 Injection Moulded Cradle

3 Foam Filter

4 Injection Moulded Surround

5 Injection Moulded CAMCO Badge

1

 

2

P.20

CAMCO USER MANUAL

VORTEX POWER AMP SERIES

Page 20
Image 20
Camco 2.6, 4 manual Fans, Filter Cleaning, Vortex Filter Assembly