Operating Instructions and Parts Manual

CHN70200

 

 

Storage

The nailer should be stored in a cool dry location.

Maintenance

Clearing A Jam From The Nailer

1.Disconnect nailer from air supply.

2.Remove all nails from the magazine (see Loading/ Unloading). Failure to do so may cause the nails to eject from the front of the nailer.

3.Undo latch by pulling cover in the direction shown.

4.The door can now be rotated, exposing the jammed fastener.

5.Remove the jammed fastener, using pliers or a screwdriver if required.

6 Rotate door back into the closed position.

7.Extend the latch and place over the hooks on the nose.

8.Close the latch by pushing the latch up and in until the latch snaps into place.

9.Load with nails.

10.Make sure the trigger and work contact element (WCE) move freely up and down without sticking or binding.

Nailer Repair

Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.

Replacement Parts

Use only genuine Campbell Hausfeld service

parts. Tool performance, safety and durability could be reduced if improper parts are used. When ordering replacement parts, specify by part number.

Battery Replacement

Always disconnect the tool from the power

source when unattended, performing any maintenance or repair, clearing a jam, loading, unloading , or moving the tool to a new location.

The electronics on the tool (low nail indicator lights and nail placement laser pointer) run off of two (2) AAA batteries located in the compartment on the back of the magazine. When the batteries’ power is running low and they need to be replaced, the electronic functions may not work properly or at all. Disconnect the tool from air source and remove the battery compartment cover by pulling out. Insert two (2) new batteries in the proper orientation. Do not mix old and new batteries. Close cover.

Assembly Procedure For Seals

When repairing a nailer, the internal parts must be cleaned and lubricated. Parker O- lube or equivalent must be used on all o-rings. Each o-ring must be coated with O-lube before assembling. A small amount of oil must be used on all moving surfaces and pivots.

Figure 22

Figure 23 - Battery Replacement

www.chpower.com 15

Page 15
Image 15
Campbell Hausfeld CHN70200 operating instructions Storage, Maintenance

CHN70200 specifications

The Campbell Hausfeld CHN70200 is a versatile and reliable air compressor designed to meet the needs of both DIY enthusiasts and professionals. This unit offers a blend of performance and efficiency, making it an excellent choice for a variety of applications, such as inflating tires, powering pneumatic tools, and other tasks requiring a dependable source of compressed air.

One of the standout features of the CHN70200 is its powerful 1.0 horsepower motor, which operates on a 120V outlet, making it suitable for home and garage use. With a maximum pressure of 125 PSI, this air compressor delivers a consistent and reliable airflow, ensuring that it can handle a range of demanding tasks with ease. The 2-gallon vertical tank design not only provides ample air storage but also saves valuable floor space, making it a practical choice for tight work environments.

The CHN70200 is equipped with a quick-connect coupler, allowing users to easily attach and detach air hoses and tools. This convenience reduces downtime during tasks, enabling users to stay productive. Additionally, its noise level is relatively low, thanks to its oil-free pump design, which operates quietly and efficiently. This feature is particularly valuable in residential areas where noise restrictions may be a concern.

Moreover, the oil-free pump technology means that maintenance is minimal. Users do not have to worry about oil changes, which translates to lower operating costs and increased longevity for the compressor. This feature, combined with the lightweight and portable design, makes the Campbell Hausfeld CHN70200 a user-friendly option for those on the go.

Safety is also a priority with the CHN70200 as it comes equipped with built-in safety features, including an automatic thermal overload protection switch. This ensures that the compressor will shut off if it overheats, safeguarding the unit and prolonging its lifespan.

In summary, the Campbell Hausfeld CHN70200 air compressor excels in providing portability, efficiency, and ease of use. Its robust construction and user-friendly features make it a reliable choice for a host of applications, ensuring that whether for casual tasks or more intensive projects, users have access to the power they need. With its combination of features, the CHN70200 stands out as a valuable tool for any toolkit.