Campbell Hausfeld IN423200AV, EZ5000 Series specifications Maintenance Chart

Models: EZ5000 IN423200AV EZ5000 Series

1 36
Download 36 pages 38.05 Kb
Page 12
Image 12

Operating Instructions & Parts Manual

Maintenance Chart

 

Maintenance

 

 

Detail

 

Item

Check

Replace

Notes

 

 

 

 

 

 

Product safety

Before each use

As required

See parts listing for

 

labels

 

 

location of product

 

 

 

 

safety labels and relat-

 

 

 

 

ed part numbers.

 

 

 

 

 

 

Trigger adjust-

Before each use

 

Make sure gun shuts

 

ment

 

 

off while spraying.

 

 

 

 

 

 

Airless hose

Before each use

 

Read information on

 

 

 

 

the hang tag attached

 

 

 

 

to the high pressure

 

 

 

 

hose for instructions

 

 

 

 

on maintenance.

 

 

 

 

 

 

Suction tube

Before each use

As required

Check for nicks and

 

 

 

 

cuts.

 

 

 

 

 

 

Bypass tube

Before each use

As required

Check for nicks and

 

 

 

 

cuts.

 

 

 

 

 

 

Suction filter

Before each use

Every 100 gal.

 

 

 

and every 5 gal.

or more often if

 

 

 

 

required

 

 

 

 

 

 

 

Gun filter

Before each use

Every 100 gal.

Do not attempt to

 

 

 

 

clean gun filter, only

 

 

 

 

replace.

 

 

 

 

 

 

Roller nap

Before each use

As required

 

 

 

 

 

 

 

Outlet valve

 

Every 100 gal.

Use 3/4” wrench –

 

 

 

 

torque to 150 in-lbs.

 

 

 

 

 

 

Spray tip

Before each use

Every 20-75 gal.

Use 13/16” wrench –

 

 

 

 

torque to 135 in-lbs.

 

 

 

 

 

www.chpower.com

12

Page 12
Image 12
Campbell Hausfeld IN423200AV, EZ5000 Series specifications Maintenance Chart