Manual de Instrucciones
Model SB504000
Sujetadores
Clavos
Estos clavos para acabado de Campbell Hausfeld los puede comprar en su tienda más cercana. Si necesita ayuda para encontrar un artículo, comuníquese al
Modelo | Longitud | Calibre | Acabodo | Cabeza | Unión | Clavos por | Clavos por | |
del cuerpo | línea | Caja | ||||||
|
|
|
|
| ||||
FB001600 | 15,9mm (5/8") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 5000 | |
FB002000 | 19,1mm (3/4") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 5000 | |
FB002500 | 25,4mm (1") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 5000 | |
FB003000 | 31,8mm (1 1⁄4") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 5000 | |
FB004000 | 3,81 cm(1 1⁄2") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 5000 | |
FB004500 | 4,45cm(1 3⁄4") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 5000 | |
FB005000 | 5,08cm (2") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 5000 | |
FB180016 | 15,9mm (5/8") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 1000 | |
FB180025 | 25,4mm (1") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 1000 | |
FB180030 | 31,8mm (1 1⁄4") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 1000 | |
FB180040 | 3,81 cm(1 1⁄2") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 1000 | |
FB180050 | 5,08cm (2") | Calibre 18 | Galvanizado | De puntilla/Café | Adhesivo | 100 | 1000 |
Información de intercambio
Los clavos usados con la SB504000 también se pueden usar con las clavadoras: Bostitch
Grapas
Estas grapas para acabado de Campbell Hausfeld los puede comprar en su tienda más cercana. Si necesita ayuda para encontrar un artículo, comuníquese al
Modelo | Longitud | Calibre de Corona | Punta | Acabado | Fusión de | Grapes | Grapes | ||
|
|
| la grapa |
|
|
| la linea | por linea | por caja |
|
|
|
|
|
|
|
|
|
|
FN158K00 | 12,7mm (1/2") |
| 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 5000 |
FN168K00 | 15,9mm (5/8") |
| 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 5000 |
FN180615 | 12,7mm (1/2") |
| 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 1000 |
FN180620 | 19,1mm (3/4") |
| 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 1000 |
FN180625 | 25,4mm (1") |
| 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 1000 |
FN180630 | 31,8mm (1 1/4") | 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 1000 | |
FN208K00 | 19,1mm (3/4") |
| 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 5000 |
FN258K00 | 25,4mm (1/4") |
| 18 | 6,4mm (1/4") | Cincel | Galvanizado/Cubierta por vinilo | Adhesivo | 100 | 5000 |
Información de intercambio
Las grapas usadas con la SB504000 también se pueden usar con las grapadoras: Senco LN4450,
Hitachi N3804A, Duofast
General Safety Information (Continued)
●Always disconnect the tool from the power source when unattended, performing any maintenance or
repair, clearing a jam, or moving the tool to a new location. Always reconnect the air line BEFORE loading any fasteners. Do not load the tool with fasteners when either the trigger is depressed or the Work Contact Element (WCE) is engaged. The tool could eject a fastener causing death or serious personal injury.
●Always fit tool with a fitting or hose coupling
on or near the tool in such a manner that all compressed air in the
tool is discharged at the time the fitting or hose coupling is disconnected. Do not use a check valve or any other fitting which allows air to remain in the tool. Death or serious personal injury could occur.
●Never place hands or any other body parts in the fastener discharge area of the tool. The tool might eject a
fastener and could result in death or serious personal injury.
●Never carry the tool by the air hose or pull the hose to move the tool or a compressor. Keep hoses away from heat,
oil and sharp edges. Replace any hose that is damaged, weak or worn. Personal injury or tool damage could occur.
●Always assume the tool contains fasteners. Respect the tool as a working implement; no horseplay. Always keep others at a safe distance from the work area in case of accidental discharge of fasteners. Do not point the tool toward yourself or anyone whether it contains fasteners or not. Accidental triggering of the tool could result in death or serious personal injury.
●Do not drive a fastener on top of other fasteners. The fastener could glance and cause death or a serious puncture wound.
●Do not operate
or allow anyone else to operate the tool if any warnings or warning labels are not legible.
Warnings or warning labels are located on the tool magazine and body.
●Do not drop or throw the tool. Dropping or throwing the tool can result in damage that will make the tool unusable or unsafe. If the tool has been dropped or thrown, examine the tool closely for bent, cracked or broken parts and air leaks. STOP and repair before using or serious injury could occur.
●Do not make any modifications to the tool without first obtaining written approval from Campbell Hausfeld. Do not use the tool if any shields or guards are removed or altered. Do not use the tool as a hammer. Personal injury or tool
damage may occur.
●Avoid long extended periods of work with the tool. Stop using the tool if you feel pain in hands or arms.
●Always check that the Work Contact Element (WCE) is operating properly. A fastener could accidentally be
driven if the WCE is not working properly. Personal injury may occur (See “Checking the Work Contact Element” Section).
●Disconnect air supply and release tension from the pusher before attempting to clear jams because fasteners can be ejected from the front of the tool. Personal injury may occur.
●Avoid using the tool when the magazine is empty. Accelerated wear on the tool may occur.
●Clean and check all air supply hoses and fittings before connecting the tool to an air supply. Replace any damaged or worn hoses or fittings. Tool performance or durability may be reduced.
●Air compressors providing air to the tool should follow the requirements established by the American National Standards Institute Standard
www.chpower.com
26 Sp | 3 |