Installation
For models supplied without a plug, fit a standard plug, suitable for the load indicated on the rating plate, onto the cable and connect to a suitable socket. To connect directly to the mains supply, a
•the limiter valve and the domestic system can withstand the load from the appliance (see rating plate);
•the supply system is efficiently earthed according to standards and laws in force;
•the socket or
Important: the wires in the mains lead are coloured in accordance with the following code:
Green & Yellow | - Earth |
Blue | - Neutral |
Brown | - Live |
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked “E” or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked “L” or coloured Red.
Connect the Blue wire to the terminal marked “N” or coloured Black.
FAILURE TO OBSERVE THE
Replacing the cable
Use a rubber cable of the type
The
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens Norm EN 50304
Energy consumption for Natural convection
heating mode: Convection
Declared energy consumption for Forced convection Class
heating mode: Fan assisted
Burners and nozzles specifications
Table 1 |
|
|
|
|
| Liquid gas |
|
| Natural gas | ||
|
|
|
|
|
|
|
|
|
| ||
| Diameter | Thermal power | Injector | Flow * | Injector | Flow* | |||||
| (mm) | kW (H.s.*) | 1/100 | 1/100 |
| g/h | 1/100 | l/h | |||
BURNER |
| Nomin. |
| Reduc. | (mm) | (mm) | G30 |
| G31 | (mm) | G20 |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
C.Rapid | 100 | 3.00 |
| 0.7 | 40 | 86 | 218 |
| 214 | 116 | 286 |
|
|
|
|
|
|
|
|
|
|
|
|
B. | 75 | 1.65 |
| 0.4 | 30 | 64 | 120 |
| 118 | 96 | 157 |
|
|
|
|
|
|
|
|
|
|
|
|
A. Auxiliary | 55 | 1.00 |
| 0.3 | 27 | 50 | 73 |
| 71 | 71 | 95 |
|
|
|
|
|
|
|
|
|
|
|
|
D. Double flame DC DR (internal) | 30 | 0.90 |
| 0.4 | 30 | 44 | 65 |
| 64 | 70 | 86 |
|
|
|
|
|
|
|
|
|
|
|
|
D. Double Flame DC DR (external) | 130 | 4.10 |
| 1.3 | 57 | 70 | 298 |
| 293 | 110 | 390 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nominal |
|
|
| 37 |
| 20 | |
Supply pressure |
|
|
| Minimum |
|
| 20 |
| 25 |
| 17 |
|
|
| Maximum |
|
| 35 |
| 45 |
| 25 | |
|
|
|
|
|
|
|
|
|
|
|
|
This appliance conforms with the following European Economic Community directives:
-73/23/EEC of 19/02/73 (Low Voltage) and subsequent modifications;
-89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and subsequent modifications;
-90/396/EEC of 29/06/90 (Gas) and subsequent modifications;
-93/68/EEC of 22/07/93 and subsequent modifications.
*At 15°C and 1013
Butane G30 H.s. = 49,47 MJ/kg Natural gas G20 H.s. = 37,78 MJ/m3
17