Canon DR-7080C manual Daily Cleaning, Cleaning the Main Unit

Models: DR-7080C

1 112
Download 112 pages 26.48 Kb
Page 98
Image 98

Chapter 7 User Maintenance

Daily Cleaning

To maintain high-quality scanning, you should periodically clean the following:

Main unit

Flatbed (Platen glass)

Pressure Board (Black)

Feeder

Before you clean the scanner, turn OFF the scanner and computer and disconnect

the power cord from the power outlet. Otherwise, an electrical shock may result. CAUTION Never clean the scanner with any kind of organic solvent, such as alcohol, benzene,

or paint thinner. It might cause a fire and electrical shock, or cause the exterior of the scanner to disfigure or discolor.

Never spray detergent or water directly onto the flatbed (platen glass). Sprayed liquid can get inside the scanner and soil the light source and lens.

Overuse of water and allowing the scanner to become too wet during cleaning can damage scanned documents and cause malfunction of the scanner.

Cleaning the Main Unit

Wipe the scanner with a firmly wrung cloth moistened slightly with water or mild detergent. Then wipe off with a clean, dry cloth.