Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont)

 

NOMINAL

VOLTAGE

COMPRESSOR

OFM

IFM

POWER

 

 

ELECTRIC HEAT

POWER SUPPLY

CRSINGLE

DISCONNECT SIZE

 

RANGE

(EA.)

 

 

UNIT

POWER SUPPLY

 

 

EXHAUST

IFM

 

 

 

 

PART NO.

 

WIRING

 

 

 

 

 

 

 

 

 

 

50PG

 

 

 

 

 

TYPE

CRHEATER

NOMINAL

 

 

 

FIG. NO.

VOLTS-PH-HZ MIN MAX

RLA

LRA FLA

FLA

FLA

MCA

MOCP†

(NOTE3)

FLA

 

 

PART NO.

FLA

LRA

 

 

 

 

 

 

 

 

 

KW*

 

 

 

 

 

50PG03−16

 

 

 

 

 

 

 

 

 

239A00

 

 

 

 

 

 

 

 

Low

240A00

 

 

 

 

 

 

 

 

 

241A00

08

575-3-60

518

632

6.4

30.0

0.8

2.8

3.0

242A00

(cont)

(cont)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

239A00

 

 

 

 

 

 

 

 

High

240A00

 

 

 

 

 

 

 

 

 

241A00

 

 

 

 

 

 

 

 

 

242A00

 

 

 

 

 

 

 

 

 

225A00

 

 

 

 

 

 

 

 

Low

226A00

 

 

 

 

 

 

 

 

227A00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

228A00

 

 

 

 

 

 

 

 

 

229A00

 

 

 

 

 

 

 

 

 

225A00

 

 

 

 

 

 

 

 

High

226A00

 

 

 

 

 

 

 

 

227A00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

228A00

 

208/230-3-60 187

253

16.0

91

1.5

5.2

 

229A00

 

 

 

225A00

226A00 Low 227A00

228A00

229A00

09

3.0

225A00

226A00 High 227A00

228A00

229A00

232A00

233A00

2.6Low 234A00

235A00

236A00

460-3-60

414 506

46

0.8

232A00

233A00

4.8High 234A00

235A00

236A00

 

 

LEGEND

FLA

Full Load Amps

HACR −

Heating, Air Conditioning and Refrigeration

IFM

Indoor − Fan Motor

LRA

Locked Rotor Amps

MCA

Minimum Circuit Amps

MOCP −

Maximum Overcurrent Protection

NEC

National Electrical Code

OFM

Outdoor−Fan Motor

RLA

Rated Load Amps

*Heater capacity (kW) is based on heater voltage of 208 v, 240 v, or 480 v. If power distribu- tion voltage to unit varies from rated heater voltage, heater kW will vary accordingly.

Fuse or HACR circuit breaker.

NOTES:

1.In compliance with NEC requirements for multimotor and combination load equip- ment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.

2.Unbalanced 3-Phase Supply Voltage

Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance.

max voltage deviation from average voltage

% Voltage Imbalance

= 100 x

average voltage

 

 

18.1

20

 

19

86

 

13.9

15.0

23.6

25

030A00

22

86

15

23.1

25.0

35.1

40

030A00

32

86

15

32.3

35.0

46.7

50

030A00

43

86

15

37.0

40.0

52.4

60

030A00

48

86

15

 

 

18.9

25

 

20

98

 

13.9

15.0

24.6

25

030A00

23

98

15

23.1

25.0

36.1

40

030A00

33

98

15

32.3

35.0

47.7

50

030A00

44

98

15

37.0

40.0

53.4

60

030A00

49

98

15

 

 

 

 

 

46/

218/218

 

20.0/23.1

 

 

 

030A00

46/

218/218

15

30.0/34.6

11.3/15.0

 

 

030A00

46/

218/218

15

50.0/57.7

18.8/25.0

 

 

031A00

64/

218/218

16

70.0/80.8

26.3/35.0

 

100/110

031A00

87/

218/218

17

80.0/92.4

30.0/40.0

106.6/122.0

110/125

031A00

98/112

218/218

17

 

 

 

 

 

 

261/261

 

20.0/23.1

 

 

 

030A00

 

261/261

15

30.0/34.6

11.3/15.0

 

 

030A00

 

261/261

15

50.0/57.7

18.8/25.0

 

 

031A00

 

261/261

16

70.0/80.8

26.3/35.0

100.3/113.8

110/125

031A00

 

261/261

17

80.0/92.4

30.0/40.0

112.8/128.2

125/150

031A00

104/118

261/261

17

 

 

 

 

 

 

222/222

 

20.0/23.1

 

 

 

030A00

 

222/222

15

30.0/34.6

11.3/15.0

 

 

030A00

 

222/222

15

50.0/57.7

18.8/25.0

 

 

031A00

 

222/222

16

70.0/80.8

26.3/35.0

 

100/125

031A00

 

222/222

17

80.0/92.4

30.0/40.0

110.3/125.7

125/150

031A00

101/116

222/222

17

 

 

 

 

 

 

265/265

 

20.0/23.1

 

 

 

030A00

 

265/265

15

30.0/34.6

11.3/15.0

 

 

030A00

 

265/265

15

50.0/57.7

18.8/25.0

 

 

031A00

 

265/265

16

70.0/80.8

26.3/35.0

104.1/117.5

110/125

031A00

 

265/265

17

80.0/92.4

30.0/40.0

116.6/132.0

125/150

031A00

107/121

265/265

17

 

 

20.1

25

 

21

110

 

11.5

10.0

20.1

25

030A00

21

110

15

17.3

15.0

24.9

25

030A00

23

110

15

28.9

25.0

39.3

40

030A00

36

110

15

40.4

35.0

53.8

60

030A00

49

110

15

46.2

40.0

61.0

70

033A00

56

110

19

 

 

22.3

25

 

24

132

 

11.5

10.0

22.3

25

030A00

24

132

15

17.3

15.0

27.7

30

030A00

25

132

15

28.9

25.0

42.1

45

030A00

39

132

15

40.4

35.0

56.5

60

030A00

52

132

15

46.2

40.0

63.7

70

033A00

59

132

19

Example: Supply voltage is 460-3-60

 

AB = 224 v

 

BC = 231 v

 

AC = 226 v

224 + 231 + 226

Average Voltage =

3

 

=681

3

=227

Determine maximum deviation from average voltage.

Maximum deviation is 4 v.

Determine percent of voltage imbalance.

4

% Voltage Imbalance

= 100 x

227

= 1.76%

This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

3.Single point kits CRSINGLE028A00 and CRSINGLE030A00 are not required if field−supplied pressure connectors are used.

16

Page 16
Image 16
Carrier 50PG03-16 installation instructions Type Crheater Nominal

50PG03-16 specifications

The Carrier 50PG03-16 is a notable air conditioning unit designed for residential and light commercial applications. This model stands out due to its combination of efficiency, durability, and innovative technology, making it a popular choice among homeowners and businesses looking for reliable cooling solutions.

One of the primary features of the Carrier 50PG03-16 is its high energy efficiency ratio (EER). This model meets or exceeds the latest environmental standards, which is essential for users looking to reduce their energy consumption and lower utility bills. The unit's efficient refrigerant cycle maximizes cooling output while minimizing energy use.

Carrier's commitment to using advanced technology is evident in the design of the 50PG03-16. The unit is equipped with a highly reliable scroll compressor, which not only operates quietly but also enhances the overall performance and longevity of the system. This type of compressor offers improvements in energy efficiency and reduces maintenance needs, providing peace of mind to the end user.

Another significant characteristic of the Carrier 50PG03-16 is its robust construction. The cabinet is fabricated from high-quality galvanized steel, ensuring durability and resistance to corrosion. This enhances the unit's lifespan and protects it from various environmental factors, which is particularly beneficial in regions with harsh weather conditions.

The ease of installation is another plus with this model. Designed with installers in mind, the Carrier 50PG03-16 simplifies the setup process, allowing for quick and efficient installation. This feature reduces overall labor costs while ensuring that the unit operates optimally from the start.

Furthermore, the Carrier 50PG03-16 offers compatibility with a variety of controls and accessories, allowing homeowners to tailor their system for maximum comfort. Users can integrate smart thermostats and zoning options, promoting enhanced control over indoor climates.

In conclusion, the Carrier 50PG03-16 air conditioning unit is a leading choice for those seeking an efficient, reliable, and durable cooling solution. With its innovative compressor technology, robust construction, and flexible installation features, it is designed to meet the demands of both residential and light commercial applications, ensuring a comfortable environment year-round.