ICEU070A

Final Check List

1.Is the unit in a room where ambient temperatures are above a minimum of 10oC (50oF) even in winter months?

2.Is there at least a 15 cm (6") clearance around the unit for proper air circulation?

3.Is the unit level? (IMPORTANT)

4.Have all the electrical and plumbing connections been made, and is the water supply shut-off valve open?

5.Has the voltage been tested and checked against the data plate rating?

6.Has the water supply pressure been checked to ensure a water pressure of at least 20 psi.

7.Check all refrigerant lines and conduit lines to guard against vibrations and possible failure.

8.Have the bolts holding the compressor down been checked to ensure that the compressor is snugly fitted onto the mounting pads?

9.Have the bin liner and cabinet been wiped clean?

10.Has the owner/user been given the User Manual and been instructed on the importance of periodic maintenance checks?

11.Has the Manufacturer’s registration card been filled in properly? Check for correct model and serial number against the serial plate and mail the registration card to the factory.

12.Has the owner been given the name and the phone number of the authorized Ice-O-matic Service Agency serving him?

Connect Power, Water and Drain. Level the cabinet.