ICEU070A
Freeze Cycle
Average Discharge Pressure
A/C: 100 to 155 PSIG
Suction Pressure
End Freeze Cycle: 0 to 1.5 PSIG
Refrigerant Metering Device:
Capillary tube
Refrigerant Charge (R-134a)
9.5 oz.
The thermostat sensing bulb is located into a plastic tube (bulb holder) secured by two clips directly to the evaporator serpentine. This control determines the length of the freezing cycle and correspondingly the size of the cubes.
A lower setting will produce a larger cube (oversize) while a higher setting a smaller cuber (shallow size).
When closed on contacts
Fan Motor
The fan motor is electrically connected in parallel to the water pump and it operates continuously only during the freezing cycle keeping the proper head pressure by circulating air through the condenser fins.
Compressor
The hermetic compressor is used to circulate refrigerant throughout the entire system. It compresses the low pressure refrigerant vapor causing its temperature to rise and become high pressure hot vapor (hot gas) which is then released through the discharge valve.
Water Spray System
Sprays the water into each individual cup to be frozen into ice.
Page 10