ICEU070A
Water Supply And Drain Connections
General
When choosing the water supply for the ice cuber consideration should be given to:
a)Length of run
b)Water clarity and purity
c)Adequate water supply pressure
Low water pressure, below 20 psi may cause a malfunction.
Water containing excessive minerals will tend to produce cloudy colored ice cubes, plus scale
Water Supply
The recommended water supply line is a 3/8" o.d. copper tube, the water pressure must have a minimum incoming pressure of 20 psig.
Connect the tubing to the 3/4" GAS / BSPP thread water inlet fitting at the back of the ice maker. An adapter is available, the part numbers are: Water Inlet
Water Drain
The recommended drain tube is a plastic or flexible tube with 18 mm (3/4") I.D. which runs to an open trapped and vented drain.
Note: Although soft, easily kinked vinyl tubing is not recommended for a drain, a short length of ¾” ID vinyl tubing is required to connect a rigid drain tube to the 20 mm (25/32”) fitting on the back of the machine.
NOTE. The water supply and the water drain must be installed to conform to the local code. In some case a licensed plumber and/or a plumbing permit is required.
Water Inlet Connection
Water Drain Connection
Back View of Utility Connections
Page 4