ICEU070A
Operation - Electrical Sequence
The following charts illustrate which switches and components are ON or OFF during the two phases of the icemaking cycle.
Refer to the wiring diagram for reference.
FREEZING CYCLE
Electrical components | ON | OFF | |||
Compressor | • |
|
|
|
|
Water Pump | • |
|
|
|
|
Fan Motor | • |
|
|
|
|
Hot Gas Valve | • |
|
|
|
|
Inlet Water Valve | • |
|
|
|
|
Electrical Controls | CLOSE | OPEN | |||
Evaporator Thermostat (contacts | • |
|
|
| |
Evaporator Thermostat (contacts |
|
| • | ||
Bin Thermostat | • |
|
|
|
|
HARVEST CYCLE
Electrical components | ON | OFF | ||
Compressor | • |
|
| |
Water Pump |
|
| • |
|
Fan Motor (Air cooled only) |
|
| • | |
Hot Gas Valve | • |
|
|
|
Inlet Water Valve | • |
|
| |
Electrical Controls CLOSE OPEN |
|
|
|
|
Evaporator Thermostat (contacts |
|
| • | |
Evaporator Thermostat (contacts | • |
|
|
|
Bin Thermostat | • |
|
|
|
Page 9