ANGLE
IRON OR
EQUIVALENT
| (B) | |
| (A) | |
(B) |
| |
(A) ROD LOCATION |
| |
USING DIMPLE | (A) | |
LOCATORS | ||
(SEE DIMENSIONAL | ||
DWG FOR | & WASHER (4) | |
LOCATIONS) | REQD PER ROD |
(A)
(B)
(B)
(A)PREFERRED ROD LOCATION
(B)ALTERNATE ROD LOCATION
NOTES: 1. A 1 In. clearance minimum between top of furnace and combustible material.
2.The entire length of furnace must be supported when furnace is used in horizontal position.
A96633
Fig. 10ÐHorizontal Crawlspace Installation on Hanger Rods
INSTALL FURNACE
1.Position furnace in desired location.
2.Connect gas supply pipe. See Fig. 8 for typical piping entry.
3.Install
4.Connect supply- and
5.Install 24- X
Step 7ÐHorizontal Crawlspace Installation
The furnace can be installed horizontally with either the LH or RH side up. In a crawlspace, furnace can either be hung from floor joist (see Fig. 10) or installed on suitable blocks or pad. (See Fig. 9.) The furnace can be suspended from each corner by hanger bolts (4 each
Since horizontal crawlspace installation is very similar to attic installation, refer to Step 6. The installation of a sheet metal shield in front of louvered control panel is covered in Step 6. For a crawlspace installation, this same sheet metal shield must be installed above louvered control panel. Extend sheet metal shield over furnace top far enough to cover gas pipe entry hole.
Step 8ÐFilter Arrangement
Never operate unit without a filter or with filter access door removed. Failure to follow this warning could result in fire, personal injury, or death.
The 2
Step 9ÐGas Piping
Gas piping must be installed in accordance with national and local codes. Refer to the current edition of the NFGC.
Canadian installations must be installed in accordance with NSC- NGPIC and all authorities having jurisdiction.
Refer to Table 5 for recommended gas pipe sizing. Risers should be used to connect to the furnace and to the meter.
If a flexible connector is required or allowed by the authority having jurisdiction, black iron pipe shall be installed at the gas valve and extend a minimum of 2 in. outside the furnace casing.
9