Equipment Selection

Indoor & Outdoor Split Geothermal Comfort Systems

GTTable-PX1b:AirSelectionHandler Characteristicsof Coils other thanfor BrandsAbove ModelsotherthanforAbovePuron®ModelsGeothermal Split Systems

 

 

 

 

 

 

Add-on CK5P

FX4 PSC

 

Model*

Nominal

Evaporator

CFM

Capacity

Coil with TXV

Fan Coil

 

Tons*

Temp (ºF)

(MBtuh)**

AND Vspd

(not an ARI rated

 

 

 

 

 

 

 

 

 

furn.

combination)

 

 

 

 

 

 

 

 

026

- Part Load

1.5

50

530

19.2 - 22.4

A/T/W 036

018

 

 

 

 

 

 

 

 

026

- Full Load

2.0

52

880

24.2 - 28.2

A/T/W 036

030

 

 

 

 

 

 

 

 

038

- Part Load

2.5

51

700

25.2 - 29.2

A/T/W 048

036

 

 

 

 

 

 

 

 

038

- Full Load

3.0

50

1200

34.5 - 40.1

A/T 060

036

 

 

 

 

 

 

 

 

049

- Part Load

3.5

47

1000

34.3 - 39.9

A/T 060

042

 

 

 

 

 

 

 

 

049

- Full Load

4.0

48

1650

46.3 - 53.8

X060

048

 

 

 

 

 

 

 

 

064

- Full Load

5.0

48

1850

54.5 - 63.3

2 - A/T/W 036

060

 

 

 

 

 

 

 

 

*Nominal tons are at ARI/ISO 13256-1 GLHP conditions. Two-stage units may be operated in single-stage mode if desired, where smaller capacity is required. For example, a model 026 may be used as a 1-1/2 ton unit if “locked” into 1st stage operation only. If PSC fan is used, unit must be “locked” into either 1st or 2nd stage. An ECM fan is required for two-stage

operation and for ARI ratings. Size air handler for “Full Load” if operating in two-stage mode.

**When selecting an air handler based upon the above conditions, choose entering WB temperature of 67ºF. Use evaporator temperature, CFM and capacity requirements as listed above. The air handler capacity must be at least at the minimum capacity shown in the table in order for the ARI rating condition to be valid. See Figure 1 for an example selection.

Indoor Coil Selection - R-22 Units Geothermal split system heat pumps with R-22 refrigerant are rated in the ARI directory with a “generic” indoor coil match and PSC fan. Selection of air handlers that attain the published ARI ratings must meet or exceed the specifications listed in Table 2. A TXV is required. Cap tubes and fixed orifices are not acceptable.

Table 2: R-22 Air Handler Characteristics

 

 

R-22 Air

Handler Characteristics

 

 

 

 

 

 

 

 

 

 

 

Nominal

Evaporator

 

 

Capacity

Model*

 

Tons*

Temp (ºF)

 

CFM

(MBtuh)**

 

 

 

 

 

 

 

018

 

1.5

50

 

600

18.5 - 21.3

 

 

 

 

 

 

 

024

 

2.0

47

 

800

25.5 - 29.3

 

 

 

 

 

 

 

030

 

2.5

49

 

1000

31.5 - 36.2

 

 

 

 

 

 

 

036

 

3.0

48

 

1200

37.0 - 42.5

 

 

 

 

 

 

 

042

 

3.5

45

 

1400

42.2 - 48.5

 

 

 

 

 

 

 

048

 

4.0

46

 

1600

50.0 - 57.5

060

 

5.0

45

 

2000

58.0 - 66.7

* Nominal tons are at ARI/ISO 13256-1 GLHP conditions.

**When selecting an air handler based upon the above conditions, choose entering WB temperature of 67ºF. Use evaporator temperature, CFM and capacity requirements as listed above. The air handler capacity must be at least at the minimum capacity shown in the table in order for the ARI rating condition to be valid. See Figure 1 for an example selection.

Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05

47

Page 49
Image 49
Carrier GT-PX, GT-S, GT-G specifications Equipment Selection, Air Handler Characteristics