ARI/ISO/ASHRAE 13256-1

 

 

 

 

 

 

Indoor & Outdoor Split

 

 

 

 

Geothermal Comfort Systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT-GS (50YCS) & GT-S (38WQS) Performance Data - English (IP) Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Loop Heat Pump

 

Ground Water Heat Pump

Ground Loop Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Cooling 86°F

Heating 68°F

Cooling 59°F

Heating 50°F

Cooling 77°F

Heating 32°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

 

Btuh

Btuh/W

Btuh

 

Btuh

Btuh/W

Btuh

 

Btuh

Btuh/W

Btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

018

16,600

14.4

20,300

 

4.8

18,500

22.1

15,500

 

4.0

17,800

16.2

12,800

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

23,500

14.5

29,300

 

4.7

25,700

20.6

22,800

 

3.9

25,200

16.6

18,600

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

28,000

14.7

34,000

 

4.7

30,200

20.8

26,400

 

3.9

29,800

16.4

21,500

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

32,800

14.5

39,200

 

4.4

34,900

20.1

31,900

 

3.9

34,700

15.9

25,900

 

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

39,800

14.1

48,300

 

4.7

44,100

19.7

37,800

 

3.9

42,000

15.5

31,700

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

44,500

14.2

52,500

 

4.8

47,500

19.3

42,000

 

3.9

47,400

15.9

35,800

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

55,100

13.0

72,700

 

4.6

57,800

17.2

57,100

 

3.7

57,600

14.2

47,200

 

3.5

Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature.

Heating capacities based upon 68°F DB, 59°F WB entering air temperature.

All ratings based upon 208V operation.

GT-GS (50YCS) & GT-S (38WQS) Performance Data - Metric (SI) Units

 

Water Loop Heat Pump

 

Ground Water Heat Pump

 

Ground Loop Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Cooling 30°C

Heating 20°C

Cooling 15°C

Heating 10°C

Cooling 25°C

Heating 0°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

Capacity

EER

Capacity

 

COP

 

Watts

W/W

Watts

 

Watts

W/W

Watts

 

Watts

W/W

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

018

4,865

4.2

5,950

 

4.8

5,422

6.5

4,543

 

4.0

5,217

4.7

3,751

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

6,887

4.2

8,587

 

4.7

7,532

6.0

6,682

 

3.9

7.386

4.9

5,451

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

8,206

4.3

9,965

 

4.7

8,851

6.1

7,737

 

3.9

8.734

4.8

6,301

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

9,613

4.2

11,489

 

4.4

10,229

5.9

9,349

 

3.9

10,170

4.7

7,591

 

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

11,665

4.1

14,156

 

4.7

12,925

5.8

11,079

 

3.9

12,309

4.5

9,291

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

13,042

4.2

15,387

 

4.8

13,921

5.7

12,309

 

3.9

13,892

4.7

10,492

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

16,149

3.8

21,307

 

4.6

16,940

5.0

16,735

 

3.7

16,882

4.2

13,834

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature.

Heating capacities based upon 68°F DB, 59°F WB entering air temperature.

All ratings based upon 208V operation.

Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05

15

Page 17
Image 17
Carrier GT-PX specifications GT-GS 50YCS & GT-S 38WQS Performance Data English IP Units