Using the CD 306 SACD as a Digital to Analog (D/A) Converter
5. Select "AES/EBU" ,"COAXIAL" or "TOSLINK"button.
1 |
2 |
1Press the POWER button to turn on the power.
2Press the COAXIAL button.
3
COAXIAL D-IN : NONE
D-OUT: NONE A-OUT: NONE
Analog Out is the first to appears on the display, then the external digital inputs sampling frequency appears .(Example: External digital inputs sampling frequency is 192kHz)
COAXIAL
*Digital input signal can be output in digital format and analog format.
*Only linear PCM signals with a sampling frequency of 32kHz, 44.1kHz,48kHz,88.2kHz, 176.4kHz or 192kHz can be played on this set. Do not input any digital signal other than linear pulse code modulation (PCM) signals.
*When the digital sampling frequency is switched, the muting circuit is activated for 1 or 2 seconds, so the sound will stop momentarily and then start again each time the digital sample rate is changed.